Technical Specifications
| Parameter | Details |
|---|---|
| Product Name | Allen-Bradley 1794-TB3S |
| Manufacturer | Rockwell Automation (Allen-Bradley) |
| Series | FLEX I/O 1794 |
| Product Type | Terminal Base Unit |
| Function | Field wiring interface + FlexBus backplane connection |
| Wiring Method | Spring clamp (cage clamp) terminals |
| Supported Modules | Digital, analog, and specialty FLEX I/O modules |
| Terminal Capacity | Typical 16 I/O + common + voltage distribution terminals |
| Field Voltage Rating | 24 VDC / 120–125 VAC systems |
| Field Current Rating | Up to 10 A |
| FlexBus Rating | 5 VDC backplane, up to ~640 mA |
| Isolation Voltage | 125 V continuous field-to-backplane isolation |
| Wire Size | 0.34–3.3 mm² (AWG 22–12) |
| Torque / Wiring | Tool-less spring clamp, no torque required |
| Mounting Type | DIN rail |
| Enclosure Rating | IP20 (open-style) |
| Operating Temperature | -20 to 70 °C |
| Humidity | 5–95% non-condensing |
| Dimensions | ~94 × 94 × 69 mm |
| Net Weight | ~0.2–0.23 kg |
FAQ
FAQ
Q1. What is the main function of 1794-TB3S?
It is a FLEX I/O terminal base used to connect field wiring to FLEX I/O modules and provide FlexBus backplane communication.
Q2. What does the “S” mean in TB3S?
It stands for Spring Clamp, meaning it uses cage-clamp terminals for faster wiring and better vibration resistance.
Q3. What is the difference between TB3 and TB3S?
- TB3: screw clamp terminals
- TB3S: spring clamp terminals (no screwdriver needed)
Q4. What modules are compatible with TB3S?
It is used with most FLEX I/O modules (digital, analog, relay, specialty), especially 16-point and 32-point types depending on configuration.
Q5. Does TB3S process signals?
No. It only provides wiring and backplane connection. All signal processing is done by the I/O module.
Q6. What is FlexBus?
FlexBus is the internal backplane that carries power and communication between the terminal base and the module.
Q7. Can modules be replaced while powered?
Yes, FLEX I/O supports RIUP (Removal and Insertion Under Power) depending on system design.
Q8. What environments is TB3S suitable for?
It is rated for standard industrial environments, typically -20 °C to 70 °C, and is widely used in machine and process automation systems.