Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | VE5005 |
| Manufacturer | Emerson |
| Product Series | DeltaV™ S-Series / M-Series I/O System |
| Product Type | Analog Output Module |
| Application | Process Control Signal Output for Field Devices |
| Output Channels | 16 Channels per Module |
| Output Signal Type | 4–20 mA Current |
| Output Resolution | 16-bit |
| Accuracy | ±0.1% of Full Scale (Typical) |
| Load Resistance | Up to 750 Ω per Channel |
| HART Communication | Supported |
| Isolation | Channel-to-System Isolation |
| Update Rate | ~100 ms |
| Terminal Block Type | 16-Channel AO Mass Termination |
| Hot-Swap Capability | Supported |
| Communication Interface | DeltaV LocalBus |
| Power Consumption | < 15 W |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% Non-Condensing |
| Mounting Type | DeltaV S-Series Carrier Installation |
| Dimensions (L × W × H) | Approximately 263 mm × 58 mm × 28 mm |
| Weight | Approximately 0.60 kg |
| Country of Origin | United States |
FAQ
FAQ
Q1: What is the Emerson VE5005 used for?
The VE5005 is used to provide analog output signals (4–20 mA) to field devices in a process control environment.
Q2: How many output channels does the module provide?
It provides 16 analog output channels.
Q3: Does VE5005 support HART communication?
Yes, all channels support HART communication for device diagnostics and configuration.
Q4: What is the maximum load per channel?
Each channel can drive up to 750 Ω load resistance.
Q5: Can the module be replaced while the system is running?
Yes, VE5005 supports hot-swapping, enabling replacement without interrupting system operation.
Q6: What are the physical dimensions of VE5005?
The module measures approximately 263 mm × 58 mm × 28 mm.
Q7: What is the weight of the module?
The weight is approximately 0.60 kg.
Q8: Does VE5005 require calibration?
Routine calibration is generally not required, but periodic verification of output accuracy and wiring integrity is recommended for reliable operation.