| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Description |
|---|---|
| Product Name | Allen-Bradley 1715-TADIF16 |
| Part Number | 1715-TADIF16 |
| Product Type | ArmorPoint / 1715 Redundant I/O 16-Channel Digital Input Module |
| Manufacturer | Rockwell Automation (Allen-Bradley) |
| Series | 1715 Redundant I/O System |
| Function | Monitors and acquires digital input signals from field devices and transmits data to the control system through the 1715 redundant I/O architecture |
| Application | Process automation / oil & gas / power generation / critical industrial control systems |
| Input Channels | 16 digital input channels |
| Input Signal Type | 24 VDC discrete inputs |
| Input Voltage Range | 18–32 VDC |
| Input Current | Approx. 2.5 mA per channel at 24 VDC |
| Isolation | Channel-to-system isolation |
| Diagnostics | Channel status monitoring, fault diagnostics, module health indication |
| Redundancy Support | Fully compatible with 1715 redundant I/O architecture |
| Communication | Via 1715 adapter and backplane communication system |
| LED Indicators | Module status and channel status LEDs |
| Power Consumption | Approx. 3.5 W |
| Mounting Type | 1715 redundant I/O base assembly |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5–95% RH non-condensing |
| Dimensions (W × H × D) | Approx. 22 × 130 × 145 mm |
| Weight | Approx. 0.25 kg |
FAQ
FAQ
Q1: What is 1715-TADIF16 used for?
A1: It is a 16-channel digital input module used to acquire discrete field signals in Rockwell Automation 1715 redundant I/O systems.
Q2: How many input channels does the module provide?
A2: The module provides 16 digital input channels.
Q3: What input voltage does it support?
A3: It is designed for 24 VDC digital input signals with an operating range of approximately 18–32 VDC.
Q4: Does 1715-TADIF16 support redundant systems?
A4: Yes, it is specifically designed for use within the 1715 redundant I/O architecture.
Q5: What diagnostic features are available?
A5: The module provides channel status indication, module diagnostics, and fault monitoring capabilities.
Q6: What industries commonly use this module?
A6: It is widely used in oil & gas, power generation, chemical processing, and other critical process automation applications.
Q7: What are the dimensions of 1715-TADIF16?
A7: The dimensions are approximately 22 × 130 × 145 mm (W × H × D).
Q8: What is the weight of the module?
A8: The module weighs approximately 0.25 kg.