Allen-Bradley 1756-RM2K ControlLogix Redundancy Module – Technical Specifications and FAQ
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley (Rockwell Automation) |
| Model | 1756-RM2K |
| Product Type | ControlLogix Enhanced Redundancy Module |
| Function | Provides synchronization and communication between redundant ControlLogix controllers |
| Redundancy Type | Controller redundancy |
| Communication Interface | Fiber-optic |
| Number of Fiber Channels | 2 |
| Data Transmission Rate | Up to 1 Gbps |
| Compatible Controllers | ControlLogix 5560, 5570 and 5580 (subject to redundancy firmware and system compatibility) |
| Current Draw at 5.1 V DC | 1.16 A |
| Current Draw at 24 V DC | 3.4 mA |
| Maximum Power Dissipation | 6 W |
| Thermal Dissipation | 21 BTU/hr |
| Compatible Fiber Cables | 1756-RMC1 (1 m), 1756-RMC3 (3 m), 1756-RMC10 (10 m) |
| Slot Width | 1 slot |
| Compatible Chassis | 1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 |
| Conformal Coating | Yes |
| Operating Temperature | 0 to 60°C |
| Storage Temperature | -40 to 85°C |
| Relative Humidity | 5–95%, non-condensing |
| Dimensions (H × W × D) | Approx. 140 × 36 × 145 mm; estimated |
| Weight | Approx. 0.29 kg |
| Country of Origin | United States (Rockwell Automation listing; verify actual unit label) |
| Lifecycle Status | Active Mature |
FAQ
FAQ
Q1: What is the Allen-Bradley 1756-RM2K used for?
A: It is a redundancy module used in ControlLogix systems to synchronize primary and secondary controllers, helping maintain operation if the primary controller fails.
Q2: Does the 1756-RM2K support fiber-optic communication?
A: Yes. It uses fiber-optic communication for redundancy synchronization and data exchange between redundant controller chassis.
Q3: What is the difference between 1756-RM2 and 1756-RM2K?
A: Both provide the same basic redundancy functionality. The 1756-RM2K is the conformally coated version, offering additional protection against environmental contaminants.
Q4: How many 1756-RM2K modules are required for a redundant system?
A: Two modules are normally required, one installed in each redundant chassis.
Q5: Which fiber-optic cables are compatible with the 1756-RM2K?
A: Compatible cables include 1756-RMC1 (1 m), 1756-RMC3 (3 m), and 1756-RMC10 (10 m).
Q6: Which ControlLogix chassis are compatible with the 1756-RM2K?
A: It supports 1756-A4, 1756-A7, 1756-A10, 1756-A13, and 1756-A17 chassis.
Q7: What are the dimensions and weight of the 1756-RM2K?
A: Approximate dimensions are 140 × 36 × 145 mm (H × W × D), and the module weighs approximately 0.29 kg, excluding packaging.
Q8: Is the 1756-RM2K still available?
A: Rockwell Automation lists the 1756-RM2K as Active Mature, meaning it remains supported but is in a mature lifecycle stage.