Allen-Bradley 1788-CN2PAR Redundant ControlNet to PROFIBUS PA Linking Device – Technical Specifications and FAQ
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 1788-CN2PAR |
| Product Name | Redundant ControlNet to PROFIBUS PA Linking Device |
| Product Type | Industrial network gateway |
| ControlNet Interface | Redundant ControlNet network |
| PROFIBUS Interface | PROFIBUS PA |
| Network Function | Connects ControlNet systems to PROFIBUS PA field devices |
| ControlNet Connectors | BNC coaxial connectors |
| Power Supply | 24–32 V DC, 0.75 A |
| PROFIBUS PA Power | 0.5 A at 24 V DC (single trunk); 0.4 A (dual trunk) |
| Power Consumption | 260 mA at 24 V DC, without field devices |
| Power Dissipation | 12.24 W at 24 V DC |
| Isolation Voltage | 30 V continuous, basic insulation |
| Mounting | DIN rail |
| Enclosure Rating | Open-style; no enclosure rating |
| Operating Temperature | 0 to +60°C (32 to +140°F) |
| Relative Humidity | 5–95%, non-condensing |
| Temperature Code | T4 |
| Dimensions (H × W × D) | Approx. 152 × 80 × 136 mm |
| Weight | Approx. 0.57 kg (distributor-listed) |
| Country of Origin | USA (supplier-listed; verify product nameplate) |
| Lifecycle Status | End of Life, November 1, 2021 |
| Replacement | Aparian A-PAL/B PROFIBUS PA linking module |
FAQ
FAQ
Q1: What is the Allen-Bradley 1788-CN2PAR used for?
A: It provides a communication gateway between a ControlNet network and PROFIBUS PA field devices, allowing Logix-based control systems to communicate with process instrumentation.
Q2: What does the “R” in 1788-CN2PAR mean?
A: It identifies the redundant ControlNet version, which supports redundant ControlNet network connections.
Q3: Which communication protocols does it support?
A: It supports ControlNet on the controller side and PROFIBUS PA on the field-device side.
Q4: What power supply does the 1788-CN2PAR require?
A: It requires an external 24–32 V DC supply, rated at 0.75 A. It also supports PROFIBUS PA trunk power.
Q5: How many PROFIBUS PA devices can it connect?
A: The supported number depends on the network configuration, fieldbus current consumption, cable length, and power budget. Check the network design documentation before determining the maximum device count.
Q6: What is its operating temperature range?
A: The specified operating temperature range is 0 to +60°C (32 to +140°F).
Q7: Is the 1788-CN2PAR discontinued?
A: Yes. Rockwell Automation identifies the legacy 1788-CN2PAR as End of Life effective November 1, 2021. The recommended replacement is the Aparian A-PAL/B.
Q8: What are the dimensions and weight for shipping?
A: Distributor information lists approximately 152 × 80 × 136 mm and 0.57 kg net weight. These figures should be treated as reference values; confirm actual packaging dimensions and gross weight before arranging international freight.