Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Allen-Bradley 1788-EN2FFR Redundant EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device – Technical Specifications and FAQ
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Allen-Bradley |
| Manufacturer | Rockwell Automation |
| Model | 1788-EN2FFR |
| Product Name | Redundant EtherNet/IP to FOUNDATION Fieldbus H1 Linking Device |
| Product Type | Industrial network gateway / linking device |
| EtherNet/IP Interface | 2 × RJ45 Ethernet ports |
| Ethernet Cable | CAT5 STP/UTP |
| Fieldbus Protocol | FOUNDATION Fieldbus H1 |
| Fieldbus Interface | 2 sets of H1 media terminals |
| Fieldbus Capacity | Up to 16 field devices |
| Network Redundancy | Supports redundant H1 trunk and redundant linking-device configurations |
| Input Power Supply | 24–32 V DC, 0.75 A, Class 2 / SELV |
| Fieldbus Power | 0.5 A at 24 V DC (single trunk); 0.4 A at 24 V DC (dual trunk) |
| Power Consumption | 260 mA at 24 V DC, without field devices |
| Power Dissipation | 12.24 W at 24 V DC |
| Isolation Voltage | 30 V continuous, basic insulation |
| Mounting | DIN rail |
| Enclosure Rating | Open-style; no IP protection rating |
| Operating Temperature | 0 to +60°C (32 to +140°F) |
| Relative Humidity | 5–95%, non-condensing |
| Temperature Code | T4 |
| Dimensions (H × W × D) | Approx. 137 × 201 × 234 mm (based on distributor-listed dimensions; verify before shipment) |
| Weight | 0.54 kg |
FAQ
FAQ
Q1: What is the Allen-Bradley 1788-EN2FFR used for?
A: It provides a communication gateway between an EtherNet/IP network and a FOUNDATION Fieldbus H1 network, allowing Logix controllers to communicate with process instrumentation.
Q2: What does the “R” in 1788-EN2FFR mean?
A: It identifies the redundant version, which supports redundant network configurations for improved communication availability.
Q3: How many FOUNDATION Fieldbus devices can it support?
A: It can support up to 16 FOUNDATION Fieldbus H1 field devices, subject to network design and power requirements.
Q4: What power supply does the 1788-EN2FFR require?
A: It requires an external 24–32 V DC supply rated at 0.75 A. It also provides FOUNDATION Fieldbus trunk power.
Q5: What Ethernet connection does it use?
A: It uses two RJ45 Ethernet ports and CAT5 shielded or unshielded twisted-pair cable.
Q6: What is its operating temperature range?
A: The specified operating temperature range is 0 to +60°C (32 to +140°F).
Q7: Is the 1788-EN2FFR discontinued?
A: Yes. Rockwell Automation documentation states that it was discontinued on March 1, 2024. The recommended replacement is the Aparian A-FFL/B module.
Q8: What are the dimensions and weight for shipping?
A: A distributor lists approximately 9.21 × 7.91 × 5.39 inches (234 × 201 × 137 mm). The net weight is not confirmed by the manufacturer. Use actual measurements and gross weight for freight quotations.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.