Technical Specifications
| Parameter | Value |
|---|---|
| Model Number | 330103-00-11-10-02-00 |
| Total Length | 1.0 meter |
| Weight | 0.323 kg |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel (SST) |
| Probe Cable | 75Ω triaxial, fluoroethylene propylene (FEP) insulated |
| Extension Cable | 75Ω triaxial, perfluoroalkoxy (PFA) insulated |
| Maximum Operating Temperature | 177°C (350°F) standard, up to 218°C (425°F) for extended temperature range probes |
| Operating Pressure | Designed to seal differential pressure between the probe tip and case |
| Output Voltage | Proportional to the distance between the probe tip and observed conductive surface |
| Linear Range | 2 mm (80 mils), from 0.25 mm to 2.3 mm (10 mils to 90 mils) |
| Target Material Calibration | AISI 4140 steel (default calibration) |
| Minimum Target Size | 15.2 mm (0.6 in) diameter (flat target) |
| Shaft Diameter (Minimum) | 50.8 mm (2 in) |
| Frequency Response | 0 to 10 kHz, +0, -3 dB, with field wiring up to 305 meters (1000 feet) |
| Extended Temperature Range | Available for higher temperature applications (up to 500°F) |
| Tensile Strength | 330 N (75 lbf) probe case to probe lead |
FAQ
FAQ
Q1: What is the purpose of the 3300 XL 8 mm Proximity Probe?
A1: The 3300 XL 8 mm Proximity Probe is used for vibration and position measurements on fluid-film bearing machines, as well as for Keyphasor reference and speed measurements.
Q2: What is the standard operating temperature of the 3300 XL probe?
A2: The standard operating temperature for the 3300 XL probe is between -52°C to +177°C (-62°F to +350°F). Extended temperature range probes can operate up to +218°C (425°F) for the probe tip.
Q3: Can the 3300 XL 8 mm Proximity Probe be used in hazardous environments?
A3: Yes, the 3300 XL Proximity Probe has various hazardous area approvals, including CSA, ATEX, IECEx, and more for use in Class I, Zone 0 and Zone 2 environments.
Q4: What is the linear range of the 3300 XL 8 mm Proximity Probe?
A4: The linear range of the probe is 2 mm (80 mils), beginning at approximately 0.25 mm (10 mils) from the target, extending up to 2.3 mm (90 mils).
Q5: What materials can the 3300 XL 8 mm Proximity Probe be calibrated to?
A5: The default calibration is to AISI 4140 steel, but calibration to other target materials is available upon request.
Q6: How do I install the 3300 XL 8 mm Proximity Probe?
A6: The probe uses corrosion-resistant, gold-plated ClickLoc connectors that only require finger-tight torque for installation, making the process simple and tool-free.
Q7: Can the 3300 XL 8 mm Proximity Probe work in environments with high radio frequency interference?
A7: Yes, the 3300 XL Proximitor Sensor is highly immune to radio frequency interference (RFI/EMI), which allows installation in fiberglass housings without adverse effects from nearby RFI.
Q8: What is the minimum shaft diameter for using the 3300 XL 8 mm Proximity Probe?
A8: The recommended minimum shaft diameter for the probe is 50.8 mm (2 inches), with a minimum of 76.2 mm (3 inches) recommended for optimal performance.