Schneider 140CRA21210 DIO Drop Interface Technical Specifications

Parameter Specification
Product Type DIO drop interface
Complementary –
Number of Ports 1 single
Rated Supply Voltage 115/230 V AC
Supply Voltage Limits 85…276 V
Supply Frequency 47…63 Hz
Maximum Supply Current 0.2 A at 115 V
0.4 A at 230 V
Inrush Current 10 A at 115 V
20 A at 230 V
Rated Power 50 VA
Associated Fuse Rating 1.5 A
Output Voltage 5.1 V
Nominal Output Current 3 A
Minimum Load Current 0 A
Short-Circuit Protection Yes
Output Overvoltage Protection Yes
I/O Words 30 Inputs / 32 Outputs
Typical Backplanes 16 positions, 6 positions, 3 positions, 2 positions, 4 positions, 10 positions
Diagnostics on Startup RAM address, Checksum
Diagnostics during Run Time RAM address, RAM, Checksum
Power Dissipation 11 W
Connections – Terminals Terminal block, 7 poles
Module Format Standard
Resistance to Electrostatic Discharge 4 kV contact (IEC 801-2), 8 kV air (IEC 801-2)
Resistance to Electromagnetic Fields 9.1 V/m (10 V/m) 80…2000 MHz (IEC 801-3)
Ambient Air Temperature (Operation) 32…140 °F (0…60 °C)
Ambient Air Temperature (Storage) -40…185 °F (-40…85 °C)
Relative Humidity 95 % without condensation
Operating Altitude <= 16404.2 ft (5000 m)
Protective Treatment TC
Standards UL 508
Product Certifications GOST, C-tick, UL, DNV, CSA Class 1 Division 2
Package Dimensions 48 x 164 x 318 mm
Package Weight 0.708 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ for Schneider 140CRA21210 DIO Drop Interface

  • Q: What is the rated supply voltage for the 140CRA21210 DIO Drop Interface?

    • A: The rated supply voltage is 115/230 V AC.

  • Q: What is the maximum supply current for this product?

    • A: The maximum supply current is 0.2 A at 115 V and 0.4 A at 230 V.

  • Q: Does the 140CRA21210 DIO Drop Interface have short-circuit protection?

    • A: Yes, it is equipped with short-circuit protection.

  • Q: What is the nominal output current of this module?

    • A: The nominal output current is 3 A.

  • Q: What types of protection does this module have?

    • A: It includes short-circuit protection and output overvoltage protection.

  • Q: What is the power dissipation for this module?

    • A: The power dissipation is 11 W.

  • Q: What is the operating temperature range of the 140CRA21210 DIO Drop Interface?

    • A: The operating temperature range is 32…140 °F (0…60 °C).

  • Q: What are the package dimensions of the 140CRA21210 DIO Drop Interface?

    • A: The package dimensions are 48 x 164 x 318 mm.


Tags

Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message