Products Description
Honeywell CC-GDIL11 51306315-175 Digital Input Module
Honeywell CC-GDIL11 51306315-175 Digital Input Module
Honeywell CC-GDIL11 51306315-175 Digital Input Module
Honeywell CC-GDIL11 51306315-175 Digital Input Module
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

 

Technical Specifications

Parameter Specification
Input Channels 32
Galvanic Isolation 1500 VAC RMS or ±1500 VDC
Isolation Technique Optical (in IOM)
DI Power Voltage Range 18 to 30 VDC
ON Sense Voltage/Current 13 VDC (min) or 3 mA (min)
OFF Sense Voltage/Current 5 VDC (max) or 1.2 mA (max)
Input Impedance 4.2 KΩ
Absolute Delay Across Input 5 ms ± 20%
Field Resistance for ON Condition 300 Ω max @ 15 VDC
Field Resistance for OFF Condition 30 KΩ min @ 30 VDC
Input Channel Scanning Normal = 20ms; Fast = 5ms
Digital Input Resolution (SOE) 1ms
Dimensions 110 x 130 x 60 mm
Weight 0.45 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQs (Q&A Format)

Q1: What is the voltage range for the DI power supply of the Honeywell CC-GDIL11 module?
A1: The DI power voltage range for the Honeywell CC-GDIL11 module is 18 to 30 VDC.

Q2: What type of isolation does the Honeywell CC-GDIL11 module use?
A2: The module uses optical isolation in the IOM (Input Output Module).

Q3: How many input channels does the CC-GDIL11 have?
A3: The CC-GDIL11 module has 32 input channels.

Q4: What is the galvanic isolation rating for the CC-GDIL11?
A4: The galvanic isolation for the CC-GDIL11 is 1500 VAC RMS or ±1500 VDC.

Q5: What is the ON Sense Voltage/Current for the module?
A5: The ON Sense Voltage is 13 VDC (minimum) and the current is 3 mA (minimum).

Q6: What is the absolute delay across the input filter and isolation?
A6: The absolute delay is 5 ms ± 20%.

Q7: What is the field resistance required for the guaranteed ON condition?
A7: The field resistance for a guaranteed ON condition is a maximum of 300 Ω at 15 VDC.

Q8: What is the size and weight of the Honeywell CC-GDIL11 module?
A8: The module has dimensions of 110 x 130 x 60 mm and weighs 0.45 kg.