Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Item | Specification |
|---|---|
| Probe Model | Bently Nevada 330101-00-12-10-02-00 |
| System Composition | 8 mm probe + Extension cable + Proximitor Sensor |
| Total Length | 1.0 meter (3.3 feet) |
| Weight | 0.323 kg |
| Probe Diameter | 8 mm |
| Probe Housing Material | AISI 303 or 304 Stainless Steel |
| Probe Cable Type | 75Ω triaxial cable with FEP insulation |
| Min Bend Radius | 25.4 mm |
| Tensile Strength | 330 N (probe to lead), 270 N (lead to connector) |
| Probe Operating Temp | -52°C to +177°C (standard), up to +218°C for ETR tip |
| Storage Temperature | -52°C to +177°C (standard), up to +260°C for ETR cable |
| Proximitor Temp Range | -52°C to +100°C |
| Linear Range | 0.25 to 2.3 mm (-1V to -17V) |
| Recommended Gap Setting | -9 Vdc (approximately 1.27 mm) |
| Sensitivity | 7.87 V/mm (200 mV/mil) ±5% (standard 5m/1m system) |
| Frequency Response | 0 to 10 kHz (+0, -3 dB), up to 305 m field wiring supported |
| Min Target Size | 15.2 mm diameter |
| Min Recommended Shaft | 76.2 mm |
| Humidity Resistance | <3% ASF change at 93% humidity for 56 days per IEC 68-2-3 |
| Power Requirements | -17.5 Vdc to -26 Vdc (12 mA max) |
| Connector Material | Gold-plated brass or gold-plated beryllium copper |
FAQ
Frequently Asked Questions (FAQs)
Q1: What types of measurements is this probe suitable for?
A1: It is suitable for vibration, position, Keyphasor reference, and speed measurements on fluid-film bearing machinery.
Q2: Is it compliant with API 670 standards?
A2: Yes, the 3300 XL 8 mm system meets API 670 standards for mechanical configuration, linear range, accuracy, and thermal stability.
Q3: Is the probe interchangeable with legacy systems?
A3: Yes, it is electrically and mechanically compatible with older 3300 series 5 mm and 8 mm systems.
Q4: Does this model include an extension cable?
A4: No, this specific model (1.0 meter version) does not require an extension cable.
Q5: What is the temperature operating range of the probe?
A5: Standard probes operate from -52°C to +177°C; ETR tips can reach +218°C and cables up to +260°C.
Q6: Is it recommended to use connector protectors?
A6: Yes, connector protectors are recommended for enhanced environmental protection.
Q7: Does the probe require on-site calibration?
A7: No, the system is fully interchangeable and does not require matching or bench calibration.
Q8: What is the tensile strength of the cable?
A8: The probe lead to body withstands 330 N; lead to connector can handle up to 270 N.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.