Technical Specifications
| Item | Specification Description |
|---|---|
| Probe Model | 330104-00-06-10-02-05 |
| Probe Type | 3300 XL 8 mm Proximity Probe (M10x1 thread, armored) |
| Total Length | 1.0 meter |
| Weight | 0.323 kg |
| Probe Tip Material | Polyphenylene Sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 Stainless Steel |
| Cable Type | 75Ω triaxial cable with FEP insulation |
| Cable Armor Option | AISI 302 or 304 Stainless Steel with FEP outer jacket |
| Min Bend Radius | 25.4 mm |
| Recommended Torque | 7.5 N·m (66 in·lbf) to 11.2 N·m (100 in·lbf) |
| Recommended Gap | -9 Vdc [approximately 1.27 mm (50 mils)] |
| Linear Range | 0.25 mm to 2.3 mm (10 to 90 mils) |
| Standard Sensitivity | 7.87 V/mm (200 mV/mil) ±5% |
| Power Requirements | -17.5 Vdc to -26 Vdc, 12 mA typical |
| Connector Type | Gold-plated ClickLoc connector, finger-tight installation |
| Operating Temp Range | -52°C to +177°C (Standard); up to +218°C for ETR version |
| Tensile Strength | Probe to cable: 330 N; cable to extension: 270 N |
| Humidity Resistance | ASF change < 3% under 93% humidity (IEC 68-2-3 standard) |
FAQ
Frequently Asked Questions
Q1: Is this probe compliant with API 670?
A1: Yes, the 3300 XL 8 mm system meets API 670 standards for mechanical design, linear range, accuracy, and temperature stability.
Q2: What is the thread size for installation?
A2: This model uses M10x1 metric thread suitable for standard metric mounts.
Q3: What is the temperature tolerance of the probe?
A3: Standard probes operate from -52°C to +177°C. ETR versions can go up to +218°C.
Q4: Is the cable armored?
A4: Yes, this version includes stainless steel armor for enhanced protection.
Q5: Are tools required to install the connectors?
A5: No, the ClickLoc connectors are finger-tight and lock with a “click” sound.
Q6: Do the probe and extension cable require calibration together?
A6: No, all components are fully interchangeable without the need for matching or calibration.
Q7: What is the recommended minimum shaft diameter for optimal performance?
A7: A minimum shaft diameter of 76.2 mm (3 inches) is recommended to reduce crosstalk and maintain accuracy.
Q8: What are the typical applications for this probe?
A8: It’s commonly used in fluid-film bearing machines for vibration and position monitoring, Keyphasor reference, and speed measurements.