Welcome to NewPLC!

GE IC694DNM200 PACSystems RX3i DeviceNet Master Module

GE IC694DNM200 PACSystems RX3i DeviceNet Master Module

Release time:2025-05-21

Views:243

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
GE IC694DNM200 PACSystems RX3i DeviceNet Master Module
GE IC694DNM200 PACSystems RX3i DeviceNet Master Module
GE IC694DNM200 PACSystems RX3i DeviceNet Master Module
GE IC694DNM200 PACSystems RX3i DeviceNet Master Module
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

GE IC694DNM200 DeviceNet Master Module Technical Specifications

Parameter Description
Module Type DeviceNet Master Module
Platform Compatibility PACSystems RX3i, Series 90-30 (not with IC693CPU321/340)
Slot Installation Any I/O slot on RX3i or 90-30 baseplate
Max Slaves Supported 63 devices
Data Transfer Capacity Up to 255 bytes input/output per slave; 3972 bytes total per direction
Communication Baud Rates 125kbps, 250kbps, 500kbps
UCMM Support Yes, Group 2 Server
I/O Connection Types Poll, Strobe, Cyclic, Change-of-State (COS)
Messaging Support Explicit messaging, fragmented I/O, configurable scan/update rate
Communication Loss Config Configurable response to communication loss
Firmware Update Via RS-232 service port
Supported Network Nodes Up to 64 (excluding bridging)
Power Requirements 5VDC at 450mA (from PLC), 24VDC nominal from network
Network Topology Bus with limited branching (trunk/drop)
Cable Type 5-wire thick or thin shielded DeviceNet cable
Max Trunk Length (Thick) 500m@125kbps; 250m@250kbps; 100m@500kbps
Max Trunk Length (Thin) 100m for all data rates
Max Drop Length 6m per drop; total varies by speed (e.g., 156m@125kbps)
Module Dimensions 89 x 107 x 188 mm
Module Weight 0.181 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

Frequently Asked Questions (FAQ)

Q1: How many DeviceNet slaves can the IC694DNM200 master module connect to?
A1: It supports up to 63 slaves.

Q2: What DeviceNet communication speeds are supported?
A2: 125kbps, 250kbps, and 500kbps.

Q3: Can the module also act as a DeviceNet slave?
A3: Yes, it can act as a slave to another master on the bus.

Q4: Does the module support explicit messaging?
A4: Yes, including fragmented I/O and explicit messages.

Q5: Is firmware upgradeable on this module?
A5: Yes, via the RS-232 service port.

Q6: Can the module be configured using VersaPro or Logicmaster?
A6: No, only Machine Edition Logic Developer PLC v3.0 SP1 Special 2 or newer is supported.

Q7: Are there any special installation requirements?
A7: The module must be installed in an I/O slot on the CPU base.

Q8: Can the module’s behavior on communication loss be customized?
A8: Yes, the response to communication loss is configurable.


Tags

Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message