Technical Specifications
| Item | Specification |
|---|---|
| Model | ALR121-S00 |
| Interface | RS-422 / RS-485 |
| Communication Mode | Half-duplex |
| Synchronization | Start-stop synchronization |
| Transmission Speed | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps |
| Transmission Code | ASCII / Binary |
| Character Length | 7 or 8 bits |
| Stop Bit Length | 1 or 2 bits |
| Parity Check | None / Even / Odd |
| Lag Time | 1 ms (wait time before receiving after transmission ends) |
| Max. Transmission Distance | 1200 meters (total extended length) |
| Installation | Mounted on ANB10, ANB11, ANR10, AFF50, AFV series |
| Connection Method | Clamped with terminal block (M4 screws, 5 poles × 2) |
| I/O Wiring | Shielded cable (3 pairs) such as AKB161, AKB162 |
| Supported Protocols | FA-M3, Modbus, MELSEC-A, YS direct/SCIU, SLC500, PLC-S |
| Data Capacity | 1000 words/module |
| Communication Definitions | 128 definitions/module |
| Current Consumption | 0.5 A |
| Dimensions | 126.7 × 32.8 × 130 mm |
| Weight | 0.3 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What communication protocols are supported by ALR121-S00?
A1: It supports FA-M3, Modbus RTU, MELSEC-A, YS direct, YS via SCIU, SLC500, and PLC-S.
Q2: Does ALR121-S00 support multipoint communication?
A2: Yes, when using RS-485 interface, it supports multipoint communication.
Q3: How many subsystems can be connected per port?
A3: Up to 30 subsystems per port, depending on the protocol used.
Q4: Can the two ports of ALR121 use different protocols?
A4: No, both ports must use the same communication protocol.
Q5: Does ALR121 support dual-redundant communication?
A5: Yes, by installing two identical ALR121 modules in a redundant configuration.
Q6: What is the maximum supported baud rate for Modbus communication?
A6: Up to 19200 bps for Modbus.
Q7: Can ALR121 communicate with YS1000 series instruments?
A7: Yes, ALR121 supports both direct RS-485 connection and SCIU interface for YS1000/YS100 instruments.
Q8: What is the maximum transmission distance of ALR121?
A8: The maximum is 1200 meters when using RS-422/RS-485 interface.