Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Honeywell MU-TDIA12 51304439-100 Technical Specifications
| Parameter | Description |
|---|---|
| Model | MU-TDIA12 |
| Input Channels | 32 |
| Input Type | Digital Input, Isolated, 120 Vac |
| Rated Input Voltage | 90-132 Vac (rms) |
| Input Frequency | 47-63 Hz |
| Isolation Method | Optical isolation |
| Isolation Voltage | 1500 Vac rms or ±1500 Vdc (Field to system) |
| Sense Current (ON) | Minimum 3.5 mA |
| Sense Current (OFF) | Maximum 1.5 mA |
| Pick Up Voltage (ON) | ≥90 Vac rms |
| Drop Out Voltage (OFF) | ≤25 Vac rms |
| Input Delay | Maximum 25 ms |
| Dimensions | 462.3 x 120.7 mm |
| Weight | 0.45 kg |
| Operating Temperature | 0°C ~ 50°C |
| Storage Temperature | -40°C ~ 70°C |
| Relative Humidity | 10%~90%, non-condensing |
| Protection Level | Industrial standard compliant |
| Certification | ANSI/IEEE C37.90.1-1978 |
FAQ
Honeywell MU-TDIA12 51304439-100 FAQ
Q1: How many input channels does the MU-TDIA12 support?
A1: This module supports 32 digital input channels.
Q2: What input voltage is required for the channel to be recognized as “ON”?
A2: The input must reach at least 90 Vac rms to be considered as “ON”.
Q3: What is the isolation voltage between channels and to the system?
A3: The isolation voltage is 1500 Vac rms or ±1500 Vdc, ensuring system safety.
Q4: What is the typical input delay for the module?
A4: The maximum delay from input signal to logic state change is 25 milliseconds.
Q5: What are the typical application areas for MU-TDIA12?
A5: It is suitable for industrial automation, process control, power plants, and manufacturing applications requiring high-reliability digital signal acquisition.
Q6: What are the module’s dimensions and weight?
A6: The dimensions are 462.3 x 120.7 mm, and the weight is 0.45 kg.
Q7: What certification standards does this module comply with?
A7: It complies with ANSI/IEEE C37.90.1-1978 and other industrial standards.
Q8: What are the environmental requirements for this module?
A8: Operating temperature is 0°C ~ 50°C, humidity 10%~90% non-condensing, with industrial-grade protection.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.