Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM

Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM

Release time:2025-07-17

Views:213

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM
Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM
Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM
Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Value
Product Name Emerson KL3103X1-LS1 Line Sensing Digital Input 24 VDC Dry Contact CHARM
Power Supply (CHARM Bus) +6.3 VDC at 32 mA
Field Circuit Power +24 VDC at 10 mA
Ambient Temperature Range -40 °C to +70 °C
Shock Resistance 10g, ½ Sinewave for 11 ms
Vibration Resistance 1 mm Peak-to-Peak (2–13.2 Hz); 0.7g (13.2–150 Hz)
Airborne Contaminants Class ISA-S71.04-1985 Class G3
Relative Humidity 5%–95% Non-Condensing
Terminal Block Key Position 2C
Dimensions 120 × 150 × 45 mm
Weight 0.5 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the power requirement of the KL3103X1-LS1 on the CHARM bus?
A1: It requires +6.3 VDC at 32 mA from the CHARM bus.

Q2: What voltage and current does the field circuit of KL3103X1-LS1 operate at?
A2: The field circuit operates at +24 VDC and 10 mA.

Q3: What is the allowable ambient temperature range for this module?
A3: The module can operate within a temperature range of -40 °C to +70 °C.

Q4: Does this module support use in hazardous locations?
A4: Yes, it is approved for use in Zone 2 and Class I, Division 2 hazardous areas.

Q5: Is calibration or adjustment required during maintenance?
A5: No calibration or adjustment is required; the unit contains no user-serviceable parts.

Q6: Can the module be removed or inserted with power energized?
A6: No, unless the area is confirmed to be non-hazardous, it must not be removed or inserted with system power on.

Q7: How does the module ensure correct terminal block compatibility?
A7: It uses a keying system to prevent incorrect installation on incompatible terminal blocks.

Q8: What is the vibration resistance specification of this module?
A8: The module withstands 1 mm peak-to-peak from 2–13.2 Hz and 0.7g from 13.2–150 Hz.