Welcome to NewPLC!

Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM

Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM

Release time:2025-07-18

Views:179

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM
Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM
Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM
Emerson KL3105X1-BA1 Intrinsically Safe Thermocouple / mV CHARM
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Model Number KL3105X1-BA1
Description Intrinsically Safe Thermocouple / mV CHARM
Power Supply (CHARM Bus) +6.3 VDC at 0 mA
Field Circuit Power Rating +24 VDC at 23 mA
Operating Temperature Range -40°C to +70°C
Shock Resistance 10g ½ Sinewave for 11ms
Vibration Resistance 1mm P-P (2–13.2Hz), 0.7g (13.2–150Hz)
Airborne Contaminants ISA-S71.04-1985 Class G3
Relative Humidity 5% to 95% Non-Condensing
Terminal Block Key Position C5
Dimensions (W x H x D) 7.62 x 76.2 x 114.3 mm
Weight 0.4 kg
Certifications ATEX, IECEx, FM, UKEX (details in datasheet)

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the function of the KL3105X1-BA1 module?
A1: It is an intrinsically safe thermocouple/mV input CHARM for hazardous area temperature or millivolt signal measurement.

Q2: Is calibration required for the KL3105X1-BA1?
A2: No, this unit does not require calibration.

Q3: Can the KL3105X1-BA1 be inserted or removed while the system is powered?
A3: No, the module cannot be removed or inserted with system power energized.

Q4: What environmental conditions can the KL3105X1-BA1 withstand?
A4: It can operate from -40°C to +70°C, with up to 95% relative humidity (non-condensing), and meets shock and vibration standards.

Q5: Are there any user-serviceable parts in the KL3105X1-BA1?
A5: No, it contains no user-serviceable parts and should not be disassembled.

Q6: Which hazardous area certifications does it have?
A6: The module is certified for ATEX, IECEx, FM, and UKEX hazardous locations.

Q7: What is the terminal block key position of the KL3105X1-BA1?
A7: The terminal block key position is C5.

Q8: What is the vibration resistance specification of the KL3105X1-BA1?
A8: It is designed to withstand 1mm peak-to-peak vibration from 2–13.2Hz and 0.7g from 13.2–150Hz.