Technical Specifications
| Parameter | Value |
|---|---|
| Sensor Model | Epro PR6423/10R-040-HT |
| Converter Model | CON021 |
| Measurement Principle | Eddy Current, non-contact |
| Linear Measurement Range | 2 mm (80 mils) |
| Initial Air Gap | 0.5 mm (20 mils) |
| Incremental Scale Factor (ISF) | 8 V/mm (203.2 mV/mil) ±5% (0–45°C) |
| Deviation from Straight Line | ±0.025 mm (±1 mil) (0–45°C) |
| Minimum Shaft Diameter | 25 mm |
| Target Material | 42CrMo4 (AISI/SAE 4140) standard |
| Protection Class (Sensor) | IP66 |
| Protection Class (Converter) | IP20 |
| Operating Temperature (Sensor) | -35°C to +180°C |
| Operating Temperature (Converter) | -30°C to +100°C |
| Frequency Range (Converter) | 0–20,000 Hz |
| Rise Time (Converter) | <15 µs |
| Supply Voltage (Converter) | -21V to -32V |
| Output Voltage Range (Converter) | -2V to -18V / -4V to -20V |
| Sensor Tip Material | PEEK |
| Sensor Case Material | Stainless Steel |
| Cable Material | PTFE |
| Connector | Lemo-plug |
| Certifications | CE, ATEX, IECEx, CSA (Intrinsic Safety and Non-sparking) |
| Hazardous Area Rating | T6/T4/T3 depending on ambient temperature |
| Sensor Head Diameter | 8 mm |
| Weight (Sensor + 1m cable) | ~0.22 kg |
| Weight (Converter) | ~0.12 kg |
FAQ
FAQ
Q1: What machinery is this sensor suitable for?
A1: It is suitable for critical rotating machinery such as steam, gas, and hydro turbines, compressors, gearboxes, pumps, and fans.
Q2: What is the linear measurement range?
A2: The PR6423 offers a linear range of 2 mm with an initial air gap of 0.5 mm.
Q3: What is the minimum shaft diameter required?
A3: The minimum shaft diameter is 25 mm.
Q4: What is the operating temperature range?
A4: The sensor operates from -35°C to +180°C, and the CON021 converter operates from -30°C to +100°C.
Q5: What are the protection classes?
A5: The sensor has IP66 protection and the converter has IP20 protection.
Q6: What is the output voltage range?
A6: Depending on supply voltage, the output voltage range is either -2V to -18V or -4V to -20V.
Q7: Is the product certified for hazardous areas?
A7: Yes, it complies with ATEX, IECEx, and CSA certifications for Intrinsic Safety (ia) and Non-sparking (nA) protection.
Q8: What are the sensor head dimensions and weight?
A8: The sensor head has a diameter of 8 mm and weighs approximately 0.22 kg including a 1-meter cable.