Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | PR6423 Eddy Current Sensor | CON021 Signal Converter |
|---|---|---|
| Linear Measurement Range | 2 mm (80 mils) | 8 mm (standard range) |
| Initial Air Gap | 0.5 mm (20 mils) | — |
| Incremental Scale Factor (ISF) | 8 V/mm (203.2 mV/mil) ±5% (0–45°C) | — |
| Deviation from Straight Line (DSL) | ±0.025 mm (±1 mil) (0–45°C) | ≤1.5% (standard range) |
| Frequency Range (-3 dB) | — | 0–20000 Hz |
| Rise Time | — | <15 µs |
| Minimum Shaft Diameter | 25 mm (0.79”) | — |
| Target Material | 42CrMo4 (AISI/SAE 4140) | — |
| Protection Class | IP66 | IP20 |
| Operating Temperature Range | Sensor: -35 to +180°C Cable: -35 to +150°C |
-30 to +100°C |
| Sensor Tip Material | PEEK | — |
| Sensor Case Material | Stainless Steel | LMgSi 0.5 F22 |
| Cable Material | PTFE | — |
| Weight | 0.22 kg (sensor head diameter 8 mm) | ~0.12 kg |
| Dimensions | Thread M10x1 or 3/8-24 UNF Cable Ø2.8mm |
56 × 41 × 18 mm (approx.) |
| Supply Voltage Range | — | -23V to -32V (output -4V to -20V) |
| Certifications | CE, ATEX, IECEx, CSA | CE, ATEX, IECEx, CSA |
| Hazardous Area Approvals | Intrinsic Safety (ia), Non-sparking (nA) | Intrinsic Safety (ia), Non-sparking (nA) |
FAQ
FAQ
Q1: What is the measurement range of the PR6423 sensor?
A1: The PR6423 sensor has a linear measurement range of 2mm (80 mils).
Q2: What is the operating temperature range of the sensor?
A2: The sensor operates from -35°C to +180°C, and the cable operates up to +150°C.
Q3: What is the minimum shaft diameter that PR6423 can measure?
A3: The minimum measurable shaft diameter is 25mm (0.79 inches).
Q4: What materials are used in the PR6423/002-100-CN?
A4: The sensor tip is PEEK, the housing is stainless steel, and the cable is PTFE.
Q5: What is the frequency response of the CON021 converter?
A5: The frequency range of CON021 is 0Hz to 20kHz (-3 dB).
Q6: What is the supply voltage for the signal converter?
A6: The supply voltage range is -23V to -32V.
Q7: Are PR6423+CON021 suitable for hazardous areas?
A7: Yes, both are certified for use in hazardous areas with ATEX, IECEx, and CSA approvals (ia and nA).
Q8: What is the weight and diameter of the PR6423 sensor?
A8: The sensor head diameter is 8mm and the weight is approximately 0.22 kg.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.