Technical Specifications
| Parameter | Specification |
|---|---|
| Model | SAI143-H33 S2 |
| Module Type | 16-channel Analog Input Module, Current Input 4–20 mA, Module Isolation |
| Number of Input Channels | 16 channels, module isolated |
| Rated Input Range | 4 to 20 mA |
| Permissible Input Range | 0 to 25 mA |
| Input Impedance (Power-ON) | 250 Ω + voltage drop in input protection circuit (0.45 V max) |
| Input Impedance (Power-OFF) | ≥ 500 kΩ |
| Rated Accuracy | ±16 µA (Input range 0.05 to 23 mA, Style code S2) |
| Data Update Frequency | 40 ms |
| Temperature Drift | ±16 µA/10 °C |
| Transmitter Power Supply | 16.15 V min (20 mA), 26.4 V max (0 mA), Output current limit: 25 mA |
| 2/4-Wire Setting | Individual channel setting via setting pins |
| Withstand Voltage | 1.5 kV AC between input signal and system for 1 min (500 V AC for dedicated signal cable) |
| Maximum Current Consumption | 5 V system: 320 mA, 24 V system: 550 mA |
| Weight | 0.34 kg (pressure clamp terminal or MIL cable) |
| Dimensions | 130 × 107.5 × 32.8 mm |
| External Connection | Pressure clamp terminal, MIL cable, dedicated signal cable |
| HART Communication | Supported (SAI143-H) |
| Transmitter Power Supply ON/OFF | Available in 2-wire setting for all 16 channels simultaneously |
FAQ
FAQ
-
Q1: What is the maximum number of input channels supported by SAI143-H33 S2?
A1: The module supports 16 input channels with module isolation. Channel usage may be restricted at ambient temperatures above 60°C. -
Q2: Can the SAI143-H33 S2 module be used in a dual-redundant configuration?
A2: Yes, dual redundancy is supported by ordering an additional module with the same specifications. -
Q3: What is the input range accuracy for low-level signals below 0.05 mA?
A3: For Style code S2, rated accuracy is ±16 µA for the input range 0.05 to 23 mA. Below 0.05 mA, the accuracy may vary. -
Q4: What HART devices are supported per channel?
A4: One HART device can be connected per channel. Each channel has a dedicated power supply function. -
Q5: How does the module handle transmitter power supply control?
A5: The ON/OFF function is available in 2-wire settings for all 16 channels simultaneously, enabling reset of alarm states in connected devices. -
Q6: What are the conditions for safe voltage withstanding?
A6: The module can withstand 1.5 kV AC between input signal and system for 1 minute, or 500 V AC when using a dedicated signal cable. -
Q7: What is the data update frequency of the SAI143-H33 S2?
A7: The module updates analog input data every 40 ms. -
Q8: What is the maximum permissible input current for the module?
A8: The module allows an input current range from 0 to 25 mA, exceeding the rated range of 4 to 20 mA.