| Item | Specification |
|---|---|
| Model | 190501-12-00-01 (Velomitor CT variant) |
| Type | Low-frequency velocity transducer (“Velomitor CT”) |
| Application | Measures casing vibration velocity for cooling towers, air-cooled fan assemblies |
| Sensitivity | 3.94 mV/mm/s (100 mV/in/s) ±5 % |
| Frequency Response | 3.0 Hz to 900 Hz (±1 dB); 1.5 Hz to 1.0 kHz (±3 dB) |
| Velocity Range | Up to 63.5 mm/s peak (2.5 in/s peak) |
| Transverse Sensitivity | < 5 % of axial sensitivity |
| Output Bias | ~10.1 VDC nominal (Pin A relative to Pin B) |
| Dynamic Output Impedance | < 400 Ω typical |
| Broadband Noise Floor | ~0.229 mm/s (1.5 Hz to 1.0 kHz) |
| Base Strain Sensitivity | 0.43 mm/s per µstrain |
| Maximum Cable Length | 305 m (1,000 ft) maximum without degradation |
| Mounting Interface | 33 mm diameter mounting surface; ¼-28 or MIL studs or adhesive base options |
| Weight | < 297 g (typical) |
| Dimensions | Height: 82 mm; Mounting diameter: 33 mm |
| Operating Temperature | –40 °C to +85 °C |
| Storage Temperature | –40 °C to +100 °C |
| Approvals / Hazardous Area | Ex ia IIC T4 Ga; Ex nA IIC T4 Gc; Class I Div 1 & 2 (when installed per drawing) |
FAQ
FAQ
Q1: What is the 190501-12-00-01 transducer used for?
A1: It is a Velomitor CT low-frequency velocity transducer designed to monitor casing vibration on cooling towers, air-cooled fans, and similar low-speed rotating systems.
Q2: What sensitivity does it provide?
A2: The device provides about 3.94 mV per mm/s of velocity (≈ 100 mV per in/s), with ±5 % tolerance.
Q3: Over what frequency band does this variant operate?
A3: The transducer maintains ±1 dB response from 3 Hz to 900 Hz, and ±3 dB response from 1.5 Hz up to 1.0 kHz.
Q4: What is the maximum usable cable length?
A4: Up to 305 m (1,000 ft) of cable can be used without significant signal degradation.
Q5: What are the environmental ratings?
A5: It operates in temperatures from –40 °C to +85 °C and can be stored from –40 °C to +100 °C.
Q6: What safety or hazardous-area certifications does it carry?
A6: It supports intrinsic safety (Ex ia IIC T4 Ga) and non-arcless (Ex nA IIC T4) certifications, as well as relevant Class I Division 1/2 approvals depending on installation.
Q7: What physical dimensions and weight does it have?
A7: The typical height is 82 mm, with a mounting diameter of 33 mm, and the device weighs under 297 g.
Q8: What mounting options are available?
A8: It supports mounting via standard studs (¼-28 or MIL type), plate or adhesive mounts, and adapters for machine housings.