Welcome to NewPLC!

GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board

GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board

Release time:2025-11-27

Views:197

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board
GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board
GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board
GE IS210DTCIH1A IS200DTCIH1A Contact Input Terminal Board
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Item Specification
Model GE IS210DTCIH1A / IS200DTCIH1A
Product Type Contact Input Terminal Board
Application Scope Discrete contact signal acquisition for turbine and industrial control systems
Input Signal Type Dry contact / potential-free contact
Nominal Input Voltage 24 VDC (typical industrial control level)
Input Logic Threshold Configurable via control system logic
Channel Capacity 24 input points
Input Filtering Hardware debounce and noise suppression
Isolation Method Optical isolation per input group
Isolation Voltage 1,500 VAC (between field side and logic side)
Input Impedance > 10 kΩ
Response Time < 5 ms typical
Diagnostic Function Open-circuit, short-circuit and signal stuck monitoring (through controller logic)
Interface Type Ribbon cable / backplane connector
Mounting Type Rack-mounted
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +85°C
Operating Humidity 5–95% RH (non-condensing)
Power Consumption < 4 W
PCB Material Industrial-grade FR-4
Coating Anti-moisture conformal coating
Dimensions (L × W × H) 180 × 120 × 30 mm
Weight 0.55 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What type of input signals does this board support?
A1: The board is designed for dry contacts and potential-free contact inputs, making it suitable for limit switches, relay outputs, and mechanical status signals.

Q2: Can this board be used with both AC and DC field wiring?
A2: It is intended primarily for low-voltage DC contact circuits. AC sensing should only be used through properly rated interposing relays.

Q3: Is signal isolation provided on each channel?
A3: Isolation is implemented per input group using optocouplers to protect the controller from field-side surges and noise.

Q4: How are input states monitored by the control system?
A4: Each contact status is transmitted digitally to the controller through the backplane or ribbon cable interface for logic execution and diagnostics.

Q5: Does the board perform signal debounce?
A5: Yes, onboard hardware filtering minimizes contact bounce and transient interference before signals reach the control processor.

Q6: What happens if an input line is shorted or disconnected?
A6: Abnormal input behavior can be detected through system diagnostics, allowing alarms or fault strategies to be executed by the controller.

Q7: Can multiple boards be installed in the same rack?
A7: Yes, multiple DTCI boards can be installed within one control rack as long as slot allocation and power budget are respected.

Q8: Is firmware required for this terminal board?
A8: No firmware is stored on the board. All logic handling and configuration are managed by the main controller.


Tags

Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message