Technical Specifications
| Item | Specification |
|---|---|
| Model | 9571-10 |
| Product Name | Standard Interconnect Cable |
| Manufacturer | Bently Nevada |
| Product Type | Signal interconnection cable |
| Application | Machinery protection and monitoring systems |
| Interface Type | Instrument-to-module interconnect |
| Cable Length | 10 ft |
| Conductor Type | Multi-core shielded conductors |
| Signal Type Support | Analog and low-level instrumentation signals |
| Shielding | Overall braided shield with drain wire |
| Insulation Material | Industrial-grade PVC/XLPE |
| Jacket Material | Oil- and abrasion-resistant PVC |
| Operating Voltage | 300 V rated |
| Temperature Rating | -20°C to +75°C |
| Bending Radius | Fixed installation minimum 10× cable diameter |
| Connector Type | Industrial snap-lock connectors |
| Connector Plating | Nickel-plated contacts |
| Contact Resistance | ≤ 20 mΩ per contact |
| Insulation Resistance | ≥ 100 MΩ at 500 V DC |
| EMC Performance | High noise immunity by shielding design |
| Installation Type | Panel and rack systems |
| Environmental Protection | Industrial indoor use |
| Compatibility | Bently Nevada monitoring systems |
| Shipping Weight | 3 kg |
FAQ
FAQ
Q1: Can this cable be used for both vibration and process signals?
A1: Yes, it supports low-level analog signals such as vibration, displacement, and process inputs.
Q2: Does the cable include grounding support for noise suppression?
A2: Yes, it includes an overall shield with a drain wire for effective grounding.
Q3: Is this cable suitable for long-term continuous operation?
A3: Yes, the jacket and insulation materials are designed for continuous industrial use.
Q4: Can the cable be routed in high electromagnetic interference environments?
A4: Yes, the braided shielding provides high immunity against electromagnetic noise.
Q5: Are the connectors pre-terminated from the factory?
A5: Yes, the cable is factory-terminated and does not require field assembly.
Q6: Is this cable compatible with third-party monitoring systems?
A6: Electrical compatibility may be possible, but connector formats are optimized for Bently Nevada systems.
Q7: Can this cable be installed in cable trays with power lines?
A7: It is recommended to separate signal and power cables to reduce interference.
Q8: Does the cable support hot connection during system operation?
A8: Hot connection is not recommended to avoid signal disturbance or equipment damage.