Technical Specifications
| Parameter | Description |
|---|---|
| Product Model | ABB Bailey NKAS01-10 Analog Module Termination Cable |
| Function | Interface cable used to connect analog input/output modules to their corresponding termination units |
| System Compatibility | Designed for ABB Bailey INFI 90 and related control systems |
| Cable Type | Shielded multi-conductor signal cable suitable for industrial analog applications |
| Application | Ensures stable and low-noise transmission of analog signals between modules and termination assemblies |
| Connector Type | Factory-terminated connectors for accurate pin alignment and secure installation |
| Electrical Features | Noise-suppressed design with stable impedance for precise analog signaling |
| Environmental Rating | Industrial-grade insulation suitable for cabinet or control-room environments |
| Cable Length | 10 feet |
| Weight | 0.658 kg |
FAQ
FAQ
Q1: What types of ABB Bailey systems are compatible with the NKAS01-10 cable?
A1: It is compatible with ABB Bailey INFI 90 and associated analog module/termination unit systems.
Q2: Does the cable include shielding for noise reduction?
A2: Yes, it uses shielded conductors specifically designed to minimize electrical interference in analog circuits.
Q3: Are the connectors pre-terminated from the factory?
A3: Yes, they are pre-assembled to ensure correct wiring and reliable attachment.
Q4: Is this cable suitable for transmitting low-level analog signals?
A4: Yes, its construction supports stable transmission of low-level and precision analog signals.
Q5: Can the NKAS01-10 be routed alongside power cables?
A5: It is recommended to route signal cables separately from power lines to avoid induced noise.
Q6: Does the shielding require grounding at installation?
A6: Yes, grounding the shield at the designated termination point helps maintain optimal signal quality.
Q7: Can this cable be used as a replacement for other Bailey termination cables?
A7: It should be used specifically for its intended analog module termination interface to ensure correct pin mapping.
Q8: Is the cable suitable for long-term continuous operation in control cabinets?
A8: Yes, the materials and insulation are designed for reliable, long-term industrial service.