Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Item | Specification |
|---|---|
| Model | Bently Nevada 330130‑085‑02‑CN Extension Cable |
| Product Type | 3300 XL Standard Extension Cable |
| Cable Length | 8.5 m (27.9 ft) |
| Cable Type | Standard extension cable with connector protectors (“02”) |
| Cable Material | 75 Ω triaxial, FEP‑insulated |
| Capacitance | ~69.9 pF/m (21.3 pF/ft) typical |
| DC Resistance (Center Conductor) | Typical for 8.5 m standard cable |
| DC Resistance (Outer Conductor) | Typical for 8.5 m standard cable |
| Output Resistance | 50 Ω typical |
| Recommended Voltage | -17.5 Vdc to -26 Vdc (non‑incendive system) |
| Operating Temperature | -40 °C to +125 °C industrial range |
| Field Wiring Support | 16–24 AWG shielded triad wiring |
| Application | Connects 3300 XL Proximitor sensors/probes to monitoring modules |
| Dimensions | Cable length 8.5 m; overall assembly size depends on installation |
| Weight | ~0.4 kg |
| Approvals | Country‑specific certifications for hazardous areas (CN option) |
FAQ
FAQ
Q1: What is the purpose of the 330130‑085‑02‑CN extension cable?
A1: It extends the connection between a 3300 XL proximity sensor or Proximitor probe and the monitoring system, allowing flexible placement in industrial machinery monitoring.
Q2: What does “330130‑085‑02‑CN” mean?
A2: “085” indicates the cable length of 8.5 meters, “02” denotes a standard extension cable with connector protectors, and “CN” signifies country‑specific certifications, typically for hazardous areas.
Q3: What type of cable construction does this model use?
A3: It uses a 75 Ω triaxial cable with FEP insulation and connector protectors to maintain signal quality and protect the connection points.
Q4: What electrical performance can be expected from this cable?
A4: The cable has a typical capacitance of around 69.9 pF per meter and an output resistance of 50 Ω, supporting accurate and reliable signal transmission.
Q5: What voltage range does this cable support?
A5: It is designed to operate with a DC supply in the range of approximately -17.5 Vdc to -26 Vdc in non‑incendive industrial systems.
Q6: Is this cable suitable for use in hazardous environments?
A6: Yes, with the “CN” designation it includes country‑specific hazardous area certifications that make it appropriate for use where such approvals are required.
Q7: What should installers know about the physical size and weight?
A7: The cable is 8.5 meters long and weighs approximately 0.4 kg. Installers should plan routing and support accordingly.
Q8: What temperature conditions can this cable withstand?
A8: It can operate in typical industrial temperature ranges from about -40 °C up to +125 °C.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.