Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | KJ6001X1-BA2 |
| Manufacturer | Emerson |
| Product Series | DeltaV™ M-Series |
| Product Type | Fieldbus H1 Carrier |
| Application | Foundation Fieldbus H1 Segment Integration |
| Function | Provides mounting, power distribution, and communication interface for Fieldbus H1 modules within the DeltaV system |
| Input Power | 24 VDC at 500 mA |
| Field Power Rating | Up to 250 VAC at 6.5 A |
| Communication Protocol | Foundation Fieldbus H1 |
| Operating Temperature | -40°C to +70°C |
| Relative Humidity | 5% to 95% Non-Condensing |
| Shock Resistance | 10 g, ½ sine wave for 11 ms |
| Vibration Resistance | 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz |
| Airborne Contaminant Rating | ISA-S71.04-1985 Class G3 |
| Hazardous Area Approval | Class I, Division 2 / Zone 2 |
| Protection Rating | IP20 |
| Mounting Type | Carrier Mounting Assembly |
| Maintenance | No user-serviceable parts |
| Calibration | Not Required |
| Dimensions (L × W × H) | Approximately 203 mm × 152 mm × 51 mm |
| Weight | Approximately 0.8 kg |
| Country of Origin | United States |
FAQ
FAQ
Q1: What is the Emerson KJ6001X1-BA2 used for?
The KJ6001X1-BA2 is a Fieldbus H1 Carrier used to connect and support Foundation Fieldbus H1 communication segments within Emerson DeltaV systems.
Q2: Which communication protocol does the KJ6001X1-BA2 support?
It is designed for Foundation Fieldbus H1 communication, allowing integration of intelligent field instruments such as transmitters, positioners, and analyzers.
Q3: What are the power requirements of the KJ6001X1-BA2?
The carrier requires a 24 VDC input supply at approximately 500 mA and supports field power circuits rated up to 250 VAC at 6.5 A.
Q4: What are the dimensions of the KJ6001X1-BA2?
The unit measures approximately 203 mm × 152 mm × 51 mm, making it suitable for installation in standard DeltaV control cabinets.
Q5: How much does the KJ6001X1-BA2 weigh?
The carrier weighs approximately 0.8 kg, allowing straightforward installation and maintenance procedures.
Q6: What environmental conditions can the KJ6001X1-BA2 withstand?
It is designed for industrial environments and operates from -40°C to +70°C with relative humidity levels from 5% to 95% non-condensing.
Q7: Is the KJ6001X1-BA2 approved for hazardous locations?
Yes. The carrier is certified for Class I Division 2 and Zone 2 hazardous areas when installed according to Emerson requirements.
Q8: Does the KJ6001X1-BA2 require routine calibration or maintenance?
No. The carrier contains no user-serviceable parts and does not require calibration during normal operation. Periodic inspection of wiring and connections is generally sufficient.