Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Allen-Bradley 1756-OB8I ControlLogix Isolated Digital DC Output Module |
| Module Type | Individually isolated digital DC output module |
| Series | ControlLogix 1756 I/O family |
| Number of Outputs | 8 individually isolated DC output channels |
| Output Voltage Range | 10 – 30 V DC (nominal 12/24 V DC) |
| Output Configuration | Sink/source with individual channel isolation |
| Output Current per Point | Up to ~2 A per channel @ 30 °C, derated to ~1 A @ 60 °C |
| Total Output Current | ~8 A max (derated with temperature) |
| Isolation Voltage | ~250 V continuous between outputs and backplane |
| Backplane Current (5.1 VDC) | ~200–250 mA |
| Backplane Current (24 VDC) | ~2–3 mA |
| Power Dissipation (Max) | ~3 W @ 60 °C |
| Minimum Load Current | ~1 mA per channel |
| Surge Current per Point | ~4 A for 10 ms, repeatable |
| Output Delay Time | OFF→ON ~1 ms max, ON→OFF ~2 ms max |
| Connection Type | Removable terminal block (e.g., 1756-TBCH / 1756-TBS6H) |
| Mounting | Installed in ControlLogix chassis slot |
| Operating Temperature Range | 0 °C to 60 °C |
| Storage Temperature Range | –40 °C to 85 °C |
| Relative Humidity (Non-condensing) | 5 % to 95 % |
| Dimensions (H × W × D) | ~300 mm × 38.1 mm × 111.25 mm |
| Weight | ~0.30 kg |
FAQ
FAQ
Q1: What is the function of the 1756-OB8I module?
It provides 8 individually isolated DC output channels for controlling field devices in ControlLogix systems.
Q2: What voltage range does this module support?
It operates within 10 – 30 V DC, suitable for standard 12 V and 24 V DC systems.
Q3: How much current can each output handle?
Each channel can supply up to about 2 A at 30 °C, with derating at higher temperatures.
Q4: Does each output have isolation?
Yes, each output channel is individually isolated, improving protection and reducing electrical interference.
Q5: What type of loads can it control?
It can drive relays, solenoids, contactors, and other DC loads.
Q6: Does it require an external power supply?
Yes, an external DC power supply (typically 24 V DC) is required for field outputs.
Q7: What are the switching response times?
Typical switching times are up to ~1 ms for ON and ~2 ms for OFF transitions.
Q8: What are the physical size and weight?
The module measures about 300 mm × 38.1 mm × 111.25 mm and weighs approximately 0.30 kg.