Technical Specifications
| Parameter | Specification |
|---|---|
| Product | 1769-IR6 CompactLogix RTD / Resistance Input Module |
| Module Type | Analog RTD / resistance input module |
| Input Channels | 6 channels |
| Supported Sensor Types | RTD (Platinum, Nickel, Nickel-Iron) and resistance inputs |
| Resistance Input Range | 0–150 Ω / 0–500 Ω / 0–1000 Ω / 0–3000 Ω |
| Input Signal Types | RTD temperature sensors and resistance measurement |
| Conversion Method | Sigma-delta A/D conversion |
| Input Accuracy | ±0.05% nonlinearity |
| Open Circuit Detection | Supported (configurable response time) |
| Short Circuit Detection | Supported |
| Current Draw @ 5V DC | ~100 mA |
| Current Draw @ 24V DC | ~35 mA |
| Power Dissipation | Max ~1.5 W |
| Isolation Voltage | 720 V DC for 1 minute (channel-to-bus, reinforced isolation) |
| Communication | CompactLogix backplane |
| Status Indicators | LED per channel and module status |
| Mounting Type | DIN rail / CompactLogix chassis |
| Operating Temperature | 0 °C to 60 °C |
| Storage Temperature | –40 °C to 85 °C |
| Humidity | 5% to 95% non-condensing |
| Weight | ~0.24 kg |
| Dimensions (H × W × D) | 118 mm × 35 mm × 87 mm |
| Application | Industrial temperature and resistance signal measurement for automation systems |
FAQ
FAQ
Q1. What is the 1769-IR6 used for?
It is used to measure temperature and resistance signals from RTD sensors in industrial control systems.
Q2. How many input channels does it have?
It provides 6 individually configurable input channels.
Q3. What types of sensors are supported?
It supports RTD sensors such as platinum, nickel, and nickel-iron types, as well as resistance inputs.
Q4. What resistance ranges can it measure?
It supports 0–150 Ω, 0–500 Ω, 0–1000 Ω, and 0–3000 Ω ranges.
Q5. What is the measurement accuracy?
The module typically provides ±0.05% nonlinearity performance.
Q6. Does it support fault detection?
Yes, it supports open-circuit and short-circuit detection on input channels.
Q7. What are its physical size and weight?
It measures 118 mm × 35 mm × 87 mm and weighs approximately 0.24 kg.
Q8. What is its typical application?
It is commonly used in industrial automation systems for precise temperature monitoring and resistance measurement.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.