Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Specification |
|---|---|
| Product | 1769-IT6 CompactLogix Thermocouple / mV Input Module |
| Module Type | Analog thermocouple and millivolt input module |
| Input Channels | 6 channels |
| Supported Sensor Types | Thermocouples: B, E, J, K, N, R, S, T, C |
| Millivolt Input Range | ±50 mV / ±100 mV (configurable) |
| Input Signal Type | Thermocouple voltage + low-level mV signals |
| Cold Junction Compensation (CJC) | 2 integrated CJC sensors |
| Resolution / Conversion | Sigma-delta A/D conversion |
| Accuracy | ±0.03% full scale (typical nonlinearity) |
| Input Update Time | Configurable (filter dependent) |
| Open Circuit Detection | Supported |
| Over/Under Range Detection | Supported |
| Backplane Current Draw | ~100 mA @ 5 V DC / ~45 mA @ 24 V DC |
| Power Consumption | ~1.5 W max |
| Isolation Voltage | 720 V DC for 1 minute (channel-to-bus) |
| Input Grouping | Channel isolated groups to backplane |
| Wiring | Removable terminal block (RTB) |
| Mounting | 1769 Compact I/O slot (DIN rail / panel system) |
| Operating Temperature | 0 °C to 60 °C |
| Storage Temperature | –40 °C to 85 °C |
| Humidity (Operating) | 5 % to 95 % non-condensing |
| Weight | ~0.28 kg |
| Dimensions (H × W × D) | 118 mm × 35 mm × 87 mm |
| Application | Industrial temperature measurement using thermocouples and mV sensors |
FAQ
FAQ
Q1. What is the 1769-IT6 used for?
It is used for temperature measurement and millivolt signal acquisition in industrial automation systems.
Q2. How many input channels does it have?
It provides 6 analog input channels.
Q3. What types of sensors are supported?
It supports multiple thermocouple types including J, K, T, E, R, S, B, N, and C.
Q4. Does it support millivolt signals?
Yes, it supports ±50 mV and ±100 mV analog input signals.
Q5. What is CJC and does this module include it?
CJC (Cold Junction Compensation) is used for thermocouple accuracy; this module includes 2 built-in CJC sensors.
Q6. What is the accuracy of the module?
Typical accuracy is around ±0.03% full scale nonlinearity.
Q7. What is the response behavior?
Response time depends on configuration and filtering settings.
Q8. What are its size and weight?
It measures 118 mm × 35 mm × 87 mm and weighs approximately 0.28 kg.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.