Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | VE4002S1 |
| Manufacturer | Emerson |
| Product Series | DeltaV™ S-Series Traditional I/O |
| Product Type | Discrete Output Module |
| Application | ON/OFF Control of Field Devices |
| Output Channels | 8 Channels |
| Output Type | Sourcing 24 VDC Discrete Output |
| Maximum Load | 0.5 A per Channel |
| Module Configuration | VO Plus Card with Mass Termination Assembly |
| Terminal Block Type | 8-Channel DO Mass I/O Terminal Block |
| Isolation | Channel-to-System Isolation |
| Response Time | < 5 ms |
| Hot-Swap Capability | Supported |
| Communication Interface | DeltaV LocalBus |
| Power Consumption | Typical 5 W, Maximum 7 W |
| Operating Temperature | -40°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% Non-Condensing |
| Mounting Type | DeltaV S-Series Carrier Installation |
| Dimensions (L × W × H) | Approximately 263 mm × 58 mm × 28 mm |
| Weight | Approximately 0.22 kg |
| Country of Origin | Malaysia / United Kingdom (varies by revision) |
| Typical Applications | Solenoids, Relays, Indicator Lamps, Motor Starters |
FAQ
FAQ
Q1: What is the Emerson VE4002S1 used for?
The VE4002S1 is used to control discrete ON/OFF field devices such as solenoids, relays, motor starters, and indicator lamps in a DeltaV control system.
Q2: How many output channels does the module provide?
The module provides 8 discrete output channels.
Q3: What type of output does the VE4002S1 provide?
It provides 24 VDC sourcing discrete outputs with a maximum load of 0.5 A per channel.
Q4: Can the module be replaced while the system is running?
Yes. The VE4002S1 supports hot swapping, allowing replacement or servicing without shutting down the DeltaV system.
Q5: What are the dimensions of the VE4002S1?
The module measures approximately 263 mm × 58 mm × 28 mm.
Q6: How much does the VE4002S1 weigh?
The weight is approximately 0.22 kg.
Q7: What types of devices can be connected to this module?
Typical devices include solenoids, relays, indicator lamps, motor starters, and other 24 VDC ON/OFF actuators.
Q8: Does the VE4002S1 require routine calibration?
No routine calibration is required. Recommended maintenance includes periodic verification of output signals, wiring integrity, and module diagnostics to ensure reliable operation.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.