Welcome to NewPLC!

GE IC200MDL750J Discrete DC Output Module

GE IC200MDL750J Discrete DC Output Module

Release time:2026-07-28

Views:174

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
GE IC200MDL750J Discrete DC Output Module
GE IC200MDL750J Discrete DC Output Module
GE IC200MDL750J Discrete DC Output Module
GE IC200MDL750J Discrete DC Output Module
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Manufacturer GE Fanuc (now Emerson Automation)
Product Model IC200MDL750J
Product Type Discrete DC Output Module
Series VersaMax I/O
Function Provides digital DC output signals for controlling external field devices
Output Type Positive Logic (Sourcing) DC Output
Number of Output Points 32 points
Output Groups 2 groups of 16 outputs
Rated Output Voltage 12/24 VDC nominal
Output Voltage Range +10.2 to +30 VDC
Output Current 0.5 A maximum per point
Maximum Inrush Current 2.0 A maximum for 100 ms
Output Voltage Drop 0.3 V maximum
Output Leakage Current 0.5 mA maximum at 30 VDC
ON Response Time 0.2 ms maximum
OFF Response Time 1.0 ms maximum
Isolation 250 VAC continuous; 1500 VAC for 1 minute (field side to logic/frame ground)
Group-to-Group Isolation 250 VAC continuous; 1500 VAC for 1 minute
Point-to-Point Isolation None
External Power Supply +10.2 to +30 VDC (12/24 VDC nominal)
Backplane Current Consumption 90 mA maximum @ 5 VDC
Protection External suppression recommended for inductive loads
Internal Fuse None
Status Indicators Individual output LEDs, OK LED, FLD PWR LED
Module ID 80808080
Mounting Method VersaMax I/O Carrier Base
Compatible Systems GE Fanuc / Emerson VersaMax PLC and Distributed I/O
Operating Temperature 0°C to +60°C (32°F to +140°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Relative Humidity 5–95% RH, non-condensing
Dimensions (H × W × D) Approx. 110 × 66.8 × 50 mm (4.33 × 2.63 × 1.97 in.)
Weight Approx. 0.14 kg (0.31 lb)
Hardware Revision J
Typical Applications Solenoid Valves, Relays, Contactors, Indicator Lamps, DC Actuators
Warranty 12 Months

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the GE Fanuc IC200MDL750J used for?
The IC200MDL750J is a VersaMax 32-point discrete DC output module used to control external field devices by providing ON/OFF switching signals from a PLC or network interface unit. Typical applications include solenoid valves, relays, contactors, and indicator lamps.

Q2: How many output channels does the IC200MDL750J provide?
The module provides 32 positive logic output points, arranged as two groups of 16 outputs. This high-density design allows many DC devices to be controlled within a compact VersaMax I/O station.

Q3: What voltage and current ratings are supported by the IC200MDL750J?
The module supports 12/24 VDC nominal operation with an output voltage range of +10.2 to +30 VDC. Each output point can handle up to 0.5 A of load current.

Q4: Does the IC200MDL750J require an external power supply?
Yes. The field load power must be supplied by an external +10.2 to +30 VDC power source. The VersaMax backplane provides power only for the module electronics.

Q5: What type of loads can be connected to the IC200MDL750J?
The module is suitable for switching DC loads such as solenoid valves, relay coils, contactors, pilot lamps, and other industrial devices requiring 12/24 VDC control signals.

Q6: Does the IC200MDL750J provide electrical isolation?
Yes. The module provides optical isolation between the user field circuits and internal logic, rated at 250 VAC continuous and 1500 VAC for one minute. The two output groups are also isolated from each other, while individual output points are not isolated.

Q7: What do the LEDs on the IC200MDL750J indicate?
Each output channel has an individual LED showing its ON/OFF status. The OK LED indicates backplane power availability, while the FLD PWR LED indicates the presence of external field power.

Q8: What should be checked before replacing an IC200MDL750J module?
Before replacement, verify the VersaMax carrier compatibility, external 12/24 VDC power supply, output wiring, load current requirements, PLC hardware configuration, and field device connections to ensure correct operation after installation.