Welcome to NewPLC!

Emerson KJ3002X1-BB1 DeltaV Analog Output Module

Emerson KJ3002X1-BB1 DeltaV Analog Output Module

Release time:2025-05-13

Views:212

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
Emerson KJ3002X1-BB1 DeltaV Analog Output Module
Emerson KJ3002X1-BB1 DeltaV Analog Output Module
Emerson KJ3002X1-BB1 DeltaV Analog Output Module
Emerson KJ3002X1-BB1 DeltaV Analog Output Module
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Item Description
Model KJ3002X1-BB1
Module Type Analog Output Module (AO), 8-channel, 4-20 mA
LocalBus Power Supply 12 VDC at 150 mA
Bussed Field Power 24 VDC at 300 mA
Field Circuit per Channel 24 VDC at 23 mA
Operating Temperature 0°C to 60°C
Humidity Range 5% to 95% non-condensing
Vibration Resistance 1mm P-P (5–16Hz); 0.5g (16–150Hz)
Shock Resistance 10g, ½ Sinewave for 11 ms
Air Contaminant Level ISA-S71.04-1985 Class G3
Protection Class IP20
Terminal Block Keying A4
Dimensions 107 x 41 x 105 mm
Weight 1.13 kg
Safety Certifications ATEX (EEx nL IIC T4), Class I Div.2, T4

FAQ
Click to rate this post!
[Total: 0 Average: 0]

Frequently Asked Questions (FAQ)

Q1: How many output channels does the KJ3002X1-BB1 module support?
A1: It supports 8 analog output channels, each delivering 4-20 mA.

Q2: What is the required power supply for the module?
A2: 12 VDC at 150 mA for LocalBus and 24 VDC at 300 mA for field power.

Q3: What is the ambient temperature range for operation?
A3: The operating temperature range is 0°C to 60°C.

Q4: Is hot swapping supported for this module?
A4: Yes, under certain conditions. Field power must be disconnected, and only one module may be swapped at a time.

Q5: Does the module require calibration?
A5: No, calibration is not required as the module is factory-calibrated.

Q6: Is this module certified for hazardous areas?
A6: Yes, it has ATEX and Class I, Div.2 certifications for use in hazardous environments.

Q7: What terminal block keying does the module use?
A7: It uses terminal blocks keyed to position A4.

Q8: Can the module be replaced while the system is powered?
A8: Yes, but only when specific power conditions and inductance limits are met as per installation guidelines.


Tags

Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message