Technical Specifications
| Parameter | Specification |
|---|---|
| Model | HIMA F3331 |
| Type | 8-Fold Output Module, safety-related, testable |
| Output Load Type | Resistive or inductive |
| Output Current | Up to 500 mA per channel |
| Output Power | Max 12 W (resistive/inductive), lamp load up to 4 W |
| Short Circuit Proof | Yes |
| Internal Voltage Drop | Max. 2 V at 500 mA load |
| Output Leakage Current | Max. 350 µA |
| Output Voltage (reset state) | Max. 1.5 V |
| Short Circuit Current Range | 0.75 to 1.5 A |
| Line Break Detection Range | 0.5 to 9.5 mA |
| Max. Admissible Line Resistance | 11 Ohm (in + out) |
| Undervoltage Cutoff | ≤ 16 V |
| Operating Voltage | 24 V DC (180 mA additional load), 5 V DC (130 mA) |
| Watchdog Current Input | Max. 30 mA |
| Test Signal Duration | Max. 200 µs |
| Line Monitoring | Integrated |
| Safety Shutdown | Integrated |
| Number of Channels | 8 |
| Space Requirement | 4 TE |
| Dimension (W x H x D) | 120 × 160 × 40 mm |
| Weight | 0.109 kg |
FAQ
FAQ Q1: What types of loads can the HIMA F3331 module handle?
A1: It supports resistive and inductive loads up to 500 mA, and lamp loads up to 4 W.
Q2: Is the HIMA F3331 module short-circuit proof?
A2: Yes, it is designed to be short-circuit proof with internal protections.
Q3: What happens when the L- supply is interrupted?
A3: No output signal will be present if the L- supply is broken, ensuring safety.
Q4: Can the module monitor for line breaks?
A4: Yes, it features integrated line monitoring for safety diagnostics.
Q5: How many F3331 output modules can be used per I/O rack?
A5: Up to 10 output modules with nominal load can be installed in one I/O rack.
Q6: What is the response to undervoltage conditions?
A6: The module triggers at voltages ≤ 16 V to ensure safe operation.
Q7: Is software integration supported for diagnostics or logic?
A7: Yes, it is compatible with HB-BLD- software blocks for safety control systems.
Q8: Can modules be paralleled without external diodes?
A8: Yes, they can be directly paralleled without the need for external diodes.