Technical Specifications
| Item | Description |
|---|---|
| Model | 330780-X1-05 |
| Application | Non-contact vibration and displacement measurement (e.g., thrust, expansion) |
| Frequency Response | 0 to 8 kHz (+0, -3 dB typical) |
| Power Supply | -17.5 Vdc to -26 Vdc (no barrier), -23 Vdc to -26 Vdc (with barrier) |
| Output Sensitivity | 3.94 V/mm (100 mV/mil) ±10% |
| Recommended Gap | 2.5 mm (100 mil) |
| Linear Range | 0.5 to 4.5 mm (20 to 180 mil) |
| Extended DSL Range | 0.5 to 5.0 mm (20 to 200 mil) |
| Input Interface | Accepts one 3300 XL 11 mm probe and extension cable |
| Probe Material | PPS (tip), 304 stainless steel (case) |
| Extension Cable Material | FEP insulated 75Ω triaxial |
| Connector Material | Gold-plated brass |
| Min. Bend Radius | 25.4 mm |
| System Length | 5 m or 9 m including probe and extension cable |
| System Weight (Typical) | 0.255 kg (Proximitor Sensor) |
| Dimensions | 81.3 x 63.5 x 31.7 mm |
| Sensor Operating Temp. | -52°C to +100°C |
| Sensor Storage Temp. | -52°C to +105°C |
| Humidity | 100% condensing (non-submersible, protected connectors) |
| EMC Compliance | EN 61000-6-2 / EN 61000-6-4, CE certified |
| Hazardous Area Certifications | ATEX, IECEx, FM, CSA (multiple approvals) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What is the main application of the 330780-X1-05 Proximitor Sensor?
A1: It is primarily used for non-contact vibration and displacement measurements such as thrust position, differential expansion, and Keyphasor signal acquisition.
Q2: What system lengths are supported?
A2: The system supports total lengths of 5 or 9 meters, including probe and extension cable.
Q3: What is the operating temperature range of this device?
A3: The operating temperature range for the Proximitor Sensor is -52°C to +100°C.
Q4: Can this sensor be used in hazardous environments?
A4: Yes, it is certified for use in Zone 0 and Zone 2 environments with ATEX, IECEx approvals.
Q5: What is the output sensitivity of this system?
A5: The output sensitivity is 3.94 V/mm (100 mV/mil) with ±10% accuracy.
Q6: Does it offer good immunity to electromagnetic interference?
A6: Yes, it meets industrial EMC standards and has strong RFI/EMI immunity.
Q7: What is the recommended installation gap?
A7: The recommended gap setting is 2.5 mm (100 mil) for optimal performance.
Q8: Are the connectors secure against loosening?
A8: Yes, the connectors are gold-plated brass with ClickLoc locking mechanism for secure installation.