Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Bently Nevada 330180-X1-05 3300 XL Proximitor Sensor |
| Input | Compatible with 3300 XL 8 mm or 3300 5 mm probes and extension cables |
| Output Resistance | 50 Ω |
| Power Supply | -17.5 Vdc to -26 Vdc (standard); -23 Vdc to -26 Vdc (with safety barriers) |
| Operating Temperature Range | -52°C to +100°C |
| Storage Temperature Range | -52°C to +105°C |
| Humidity Tolerance | ≤3% ASF change at 93% RH per IEC 68-2-3 standard |
| Linear Range | 0.25 mm to 2.3 mm (10 mils to 90 mils) |
| Frequency Response | 0 to 10 kHz, ±3 dB |
| Recommended Shaft Diameter | ≥76.2 mm (3 in) |
| Recommended Gap Voltage | -9 Vdc (~1.27 mm / 50 mils) |
| Incremental Scale Factor (ISF) | 7.87 V/mm ±5% (5m); ±6.5% (9m); ±6.5% (ETR) |
| DSL Accuracy | ±0.025 mm (5m); ±0.038 mm (9m/ETR) |
| Probe Tip Material | PPS (Polyphenylene Sulfide) |
| Probe Case Material | AISI 303 or 304 Stainless Steel |
| Cable Insulation (Standard) | FEP (Fluoroethylene Propylene) |
| Cable Insulation (ETR) | PFA (Perfluoroalkoxy) |
| Minimum Cable Bend Radius | 25.4 mm (1.0 in) |
| Connector Material | Gold-plated brass / beryllium copper |
| Dimensions (Sensor Only) | 81.3 mm × 35.1 mm × 58.4 mm |
| Weight (Sensor Only) | 0.246 kg (8.67 oz) |
FAQ
Frequently Asked Questions (FAQ)
Q1: What probe types are compatible with the 330180-X1-05 Proximitor Sensor?
A1: It is compatible with 3300 XL 8 mm and legacy 3300 5 mm proximity probes.
Q2: Is the sensor compliant with API 670 standards?
A2: Yes, the complete system meets API 670 requirements including linearity, accuracy, and temperature stability.
Q3: What is the recommended operating temperature range for the sensor?
A3: The sensor operates reliably between -52°C and +100°C.
Q4: How is power supplied to the 330180-X1-05 Proximitor Sensor?
A4: It requires a DC power supply of -17.5 V to -26 V, drawing a maximum of 12 mA.
Q5: Can the sensor be used in hazardous areas?
A5: Yes, it is certified for hazardous area installations including Class I, Zone 0 and Zone 2 with appropriate barriers.
Q6: What mounting options are available for the sensor?
A6: Both panel mount and DIN-rail mount options are supported with a common 4-hole footprint.
Q7: What is the maximum cable length supported between the sensor and monitor?
A7: Up to 305 meters (1,000 feet) of field wiring is supported.
Q8: Does the system require component matching or bench calibration?
A8: No, all components are fully interchangeable and pre-calibrated for standard AISI 4140 steel targets.
Tags