Technical Specifications

Category Specification
Model Number FC-TDOL-0724P
Output Channels 7 channels
Max Output Current 2 A per channel
Output Type 24V DC, resistive or inductive load with diode
Output Voltage Range 24 V DC ±20%
No Load Voltage OFF: 90% of supply, ON: 100% of supply
Max Load Resistance 2200 Ω
Leakage Current Approx. 1.1 mA at 24 V
Short Circuit Threshold 200Ω < RTh < 400Ω
Max Switched Power 150 W
Electrical Life 100,000 operations
Mechanical Life 30,000,000 operations
Fuse Specification 2 A, 5×20 mm, 250V AC / 300V DC, Littelfuse 0213002
Power Consumption (idle) < 9 mA (Field Power)
Power (Relay + Ch8) Max 250 mA
Readback Circuit Max 275 mA (redundant SDI-1624)
Mounting Type DIN rail (TS32 / TS35 × 7.5)
Rail Length Used 241 mm
Dimensions (L×W×H) 240 × 109 × 80 mm
Weight 0.62 kg

FAQ
Click to rate this post!
[Total: 0 Average: 0]

Frequently Asked Questions (FAQ)

Q1: How many output channels does FC-TDOL-0724P support?
A1: It supports 7 individual relay contact outputs, each rated for up to 2 A.

Q2: Can inductive loads be used?
A2: Yes, inductive loads with a spark suppression diode are supported.

Q3: How is short circuit detection handled?
A3: Short circuits are detected via resistance thresholds; anything below 400Ω may trigger detection.

Q4: What is the mounting method for the module?
A4: It mounts on standard DIN EN rails, TS32 or TS35 × 7.5.

Q5: Does the module support redundancy?
A5: Yes, it works with redundant SDO-0824 and SDI-1624 modules.

Q6: Are there protective measures in place?
A6: Each output channel is protected by a 2 A fuse (5×20 mm).

Q7: What is the power consumption of the module?
A7: Idle consumption is below 9 mA; total may reach up to 275 mA under maximum load.

Q8: What certifications does FC-TDOL-0724P have?
A8: CE and TUV certified; UL and CSA certifications are pending.