Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | IC695ALG106 |
| Type | Isolated Analog Input Module (Voltage/Current) |
| Input Channels | 6 isolated channels |
| Input Signal Range | Voltage: ±10V, 0–10V, ±5V, 0–5V, 1–5V Current: 0–20mA, 4–20mA, ±20mA |
| Resolution | 16-bit ADC, output as 32-bit float or integer |
| Power from Backplane | 230 mA @ 5V, 320 mA @ 3.3V |
| External 24VDC Power | 500 mA @ 19.2–30 VDC |
| Power Dissipation | Max. 2.97 W with all channels at 20 mA input |
| Accuracy | ±0.1% of range @ 25°C, ±0.2% over full temperature range |
| Calibration Interval | Typically 12 months |
| Input Impedance (Voltage) | > 500 kΩ |
| Input Resistance (Current) | 250 Ω ±1% |
| Overvoltage Protection | ±35 VDC continuous |
| Overcurrent Protection | ±35 mA continuous |
| Isolation | 250 VAC continuous / 1500 VAC for 1 minute |
| Noise Rejection (Common Mode) | ≥100 dB @ 50/60 Hz with 8Hz/12Hz filter |
| Channel-to-Channel Crosstalk | ≤ -70 dB |
| Analog Step Response | ≤ 1.7 ms (excluding digital filtering) |
| Digital Filter Options | 8Hz, 12Hz, 16Hz, 40Hz, 250Hz, 1000Hz |
| Digital Filter Settling Time | 127 ms (8Hz), 67 ms (12Hz), 56 ms (16Hz), 21 ms (40Hz), 3.1 ms (250Hz) |
| Analog Module Scan Time | 1 ms |
| Dimensions | 34 × 140 × 145 mm |
| Weight | 0.25 kg |
FAQ
Frequently Asked Questions (FAQ)
Q1: What type of input signals does the IC695ALG106 support?
A1: It supports both voltage and current signals. Voltage ranges include ±10V, 0–10V, ±5V, 0–5V, and 1–5V. Current ranges include 0–20mA, 4–20mA, and ±20mA.
Q2: How many channels are available on this module?
A2: The IC695ALG106 module has 6 fully isolated input channels.
Q3: What is the module’s resolution?
A3: It features a 16-bit ADC, and the data can be output as either a 32-bit floating point or integer.
Q4: What kind of isolation is provided?
A4: The module provides 250 VAC continuous isolation (1500 VAC for 1 minute) between channels and from the terminal block to the backplane.
Q5: Does the module require external power?
A5: Yes, it requires an external isolated +24 VDC power source ranging from 19.2 to 30 VDC.
Q6: What CPU firmware version is required?
A6: It requires a PACSystems RX3i CPU with firmware version 5.0 or later.
Q7: How accurate is the input measurement?
A7: Accuracy is ±0.1% at 25°C and ±0.2% across the full operating temperature range.
Q8: How often should the module be calibrated?
A8: It is recommended to calibrate the module every 12 months to maintain accuracy.