Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | Bently Nevada 330101-30-49-10-02-05 3300 XL 8 mm Proximity Probe |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 Stainless Steel |
| Probe Cable Type | 75Ω triaxial, FEP insulated |
| Probe Length (Total) | 1.0 meter |
| Weight | 0.323 kg |
| Linear Range | 2 mm (80 mils), from 0.25 mm to 2.3 mm (10–90 mils) |
| Recommended Gap Setting | 1.27 mm (50 mils) |
| Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ±5% |
| Deviation from Best Line | ≤ ±0.025 mm |
| Frequency Response | 0–10 kHz, +0, -3 dB |
| Minimum Shaft Diameter | 50.8 mm (recommended ≥76.2 mm) |
| Operating Temperature Range | Probe: -52°C to +177°C |
| Storage Temperature Range | Probe: -52°C to +177°C |
| Cable Minimum Bend Radius | 25.4 mm |
| Cable Tensile Strength | 330 N (probe to lead) |
| Connector Type | Miniature coaxial ClickLoc |
| Mounting Thread | 3/8-24 UNF |
| Certifications | CSA, ATEX, IECEx approvals |
FAQ
FAQ
Q1: What is the linear measurement range of the probe?
A1: The linear measurement range is 2 mm (80 mils), from 0.25 mm (10 mils) to 2.3 mm (90 mils).
Q2: What is the recommended installation gap?
A2: The recommended installation gap is 1.27 mm (50 mils).
Q3: What is the minimum shaft diameter suitable for this probe?
A3: The minimum shaft diameter is 50.8 mm, and ≥76.2 mm is recommended for optimal performance.
Q4: What is the maximum operating temperature of this probe?
A4: The maximum operating temperature is +177°C.
Q5: What is the tensile strength of the probe and cable?
A5: The maximum tensile strength between the probe and the lead is 330 N.
Q6: What type of connector does the probe use?
A6: The probe is equipped with a Miniature coaxial ClickLoc connector with a locking mechanism to prevent loosening.
Q7: What is the frequency response of the probe system?
A7: The frequency response range of the system is 0–10 kHz, +0, -3 dB.
Q8: What certification standards does this product meet?
A8: The product complies with CSA, ATEX, and IECEx certification standards.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.