Welcome to NewPLC!

Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe

Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe

Release time:2025-07-09

Views:199

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe
Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe
Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe
Bently Nevada 330101-30-63-10-02-05 3300 XL 8 mm Proximity Probe
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Model Bently Nevada 330101-30-63-10-02-05
Product Type 3300 XL 8 mm Proximity Probe
Total Length 1.0 meter
Weight 0.323 kg
Probe Tip Diameter 8.0 mm
Probe Case Material AISI 303/304 Stainless Steel
Probe Cable Type 75Ω triaxial FEP insulated
Recommended Gap Setting 1.27 mm (50 mils)
Linear Range 2 mm (80 mils)
Frequency Response 0 to 10 kHz (+0, -3 dB)
Operating Temperature -52°C to +177°C (Standard Probe)
Storage Temperature -52°C to +177°C
Minimum Target Size 15.2 mm diameter (flat)
Shaft Diameter (min/recommended) 50.8 mm / 76.2 mm
Connector Type Miniature coaxial ClickLoc
Tensile Strength 330 N (probe case to lead), 270 N (lead to extension)
Humidity Tolerance <3% change at 93% RH over 56 days
Compliance FCC Part 15, CE, RoHS, SIL 2/3

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the recommended gap setting for this probe?
A1: The recommended gap setting is 1.27 mm (50 mils).

Q2: What is the operating temperature range of the probe?
A2: The standard probe operates from -52°C to +177°C.

Q3: What is the linear range of the 330101 probe?
A3: The linear range is 2 mm (80 mils).

Q4: What is the frequency response of the probe?
A4: The frequency response is 0 to 10 kHz (+0, -3 dB).

Q5: What is the minimum shaft diameter this probe can be used with?
A5: The minimum shaft diameter is 50.8 mm, with 76.2 mm recommended.

Q6: What are the length and weight of the probe?
A6: The total length is 1.0 meter, and the weight is 0.323 kg.

Q7: Are special tools required to install the ClickLoc connector?
A7: No, the ClickLoc connector is designed to be tightened by hand.

Q8: Does the probe comply with international certification standards?
A8: Yes, the probe meets FCC, CE, RoHS standards and supports SIL 2/3 safety levels.