Honeywell RM7850A1001 7800 SERIES Burner Control
Honeywell RM7850A1001 7800 SERIES Burner Control
Honeywell RM7850A1001 7800 SERIES Burner Control
Honeywell RM7850A1001 7800 SERIES Burner Control
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Model Honeywell RM7850A1001
Series 7800 SERIES Burner Control
Power Supply Voltage 120 Vac (+10% / -15%), 50/60 Hz (±10%)
Control Voltage 115–120 Vac
Power Dissipation (Relay Module) Max. 10 W
Maximum Load 2000 VA
Fusing 15 A (Type SC or equivalent)
Ambient Operating Temperature -40°C to +60°C (-40°F to +140°F)
Storage Temperature -40°C to +66°C (-40°F to 150°F)
Humidity 85% RH, non-condensing
Vibration 0.5G
Ignition Output 120 Vac, 2A ignition
Pilot Valve Outputs PV1 & PV2: 120 Vac, 4A, 20A inrush
Main Fuel Valve Output 120 Vac, 4A, 20A inrush
Flame Signal Input 136 to 220 Vac, current limited
Sequence Timing (Preignition) 2 seconds
Firing Rate Outputs HI, LO, MOD, COM: 120 Vac, 0.5A each
Dimensions 127 x 127 x 133 mm
Weight 0.73 kg
Flame Detection Compatibility UV or Rectification types with plug-in amplifiers
Certifications EN298, SIL3 capable, FM, CE

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What type of burner applications is the RM7850A1001 suitable for?
A1: It is designed for fully modulating burner applications using gas, oil, or combination fuels.

Q2: What is the power supply requirement for the RM7850A1001?
A2: The module operates at 120 Vac ±10%, 50/60 Hz.

Q3: What kind of flame detectors are compatible with this control?
A3: It supports UV detectors like C7027/C7035 and rectification flame rods with plug-in amplifiers such as R7847 or R7861.

Q4: Does it support flame signal self-check functionality?
A4: Yes, using dynamic self-check flame amplifiers such as R7861A.

Q5: Can the RM7850A1001 be used in SIL 3 safety systems?
A5: Yes, it is SIL 3 capable when used in an appropriately designed safety system.

Q6: What environmental conditions can it withstand?
A6: Operating temperatures from -40°C to +60°C, and 85% RH non-condensing humidity.

Q7: Is a Keyboard Display Module (KDM) required?
A7: No, it is optional, but provides additional diagnostics and configuration functions.

Q8: What are the dimensions and weight of the unit?
A8: The unit measures 127 x 127 x 133 mm and weighs 0.73 kg.