Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |

Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | IS420UCSBS1A |
| Product Type | Mark VIeS Safety Controller Module |
| Processor | Dual-core, 1.6 GHz AMD G-Series |
| Memory | 2 GB DDR3-1066 SDRAM with ECC |
| Storage | 128 GB Solid State Drive |
| Redundancy | Supports Simplex, Dual, and TMR configurations |
| Supported Protocols | Modbus TCP Slave (Read-only), EGD/UDH, OPC UA |
| IONet Ports | 3 (R, S, T) – For communication with I/O modules |
| Ethernet Port (ENET1) | For EGD/UDH, Modbus TCP Slave, and Black Channel Comm. |
| Programming Languages | FBD, RLD, Cause and Effect Matrix |
| Logic Execution Frame Rates | 10 ms, 40 ms, 80 ms, 160 ms |
| Input Voltage | 18–30 VDC, 28 VDC nominal |
| Power Consumption | Max 30.8 W |
| Operating Temperature | -40 to 70°C |
| Storage Temperature | -40 to 85°C |
| Humidity | 95% non-condensing |
| Cooling Method | Convection |
| Mounting Method | Base-mounted |
| Safety Certifications | IEC 61508 (SIL2/SIL3 compliant) |
| Hazardous Location Ratings | Class 1 Div 2 / Class 2 Zone 2 / ATEX |
| G3 Compliant | Yes |
| Dimensions (H × W × D) | 32 × 8 × 25 mm |
| Weight | 0.25 kg |
FAQ
FAQ
Q1: What redundancy configurations are supported by the IS420UCSBS1A controller?
A1: The IS420UCSBS1A supports Simplex, Dual, and Triple Modular Redundancy (TMR) configurations.
Q2: Is the IS420UCSBS1A compliant with safety standards?
A2: Yes, it complies with IEC 61508 for SIL2 and SIL3 functional safety levels.
Q3: What type of processor does the controller use?
A3: It is equipped with a dual-core 1.6 GHz AMD G-Series processor.
Q4: What communication protocols are supported?
A4: The controller supports Modbus TCP Slave (read-only), EGD/UDH, and OPC UA.
Q5: Does the controller have internal storage?
A5: Yes, it includes a 128 GB solid state drive for control logic and data storage.
Q6: What are the typical application areas for this controller?
A6: It is widely used in emergency shutdown systems, burner management, fire and gas detection, and critical safety loop control.
Q7: Is non-volatile memory supported for program variables?
A7: Yes, it supports 3,067 non-volatile program variables, 338 forces, and 64 totalizers.
Q8: Can the IS420UCSBS1A operate in harsh environments?
A8: Yes, it operates in a wide temperature range (-40°C to 70°C), is G3 compliant, and certified for use in hazardous locations (Class 1 Div 2 / Zone 2).
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.