Products Description




| Company Information | |||
| [email protected] | |||
| Mobile | +8613950166376 | ||
| +8613950166376 | |||
| 13950166376 |
Technical Specifications
| Item | Description |
|---|---|
| Product Model | Bently Nevada 136711-01 |
| Product Type | Temperature Module |
| Manufacturer | Bently Nevada |
| Function | Measures and monitors temperature signals from connected sensors in machinery protection and condition monitoring systems |
| Supported Systems | Compatible with Bently Nevada 3500 Monitoring System |
| Input Type | Thermocouple or RTD inputs |
| Number of Channels | 4 independent input channels |
| Input Range | -200°C to +850°C (depends on sensor type) |
| Accuracy | ±0.1% of full scale |
| Resolution | 16-bit analog-to-digital conversion |
| Update Rate | Configurable; typical 1 sample per second per channel |
| Communication Interface | Backplane communication with 3500 rack system |
| Power Supply | Supplied via rack backplane (nominal 24 VDC) |
| Isolation | Channel-to-channel and channel-to-ground isolation |
| Operating Temperature | 0°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5–95% non-condensing |
| Dimensions | 241.3 x 24.4 x 163.1 mm |
| Weight | 0.46 kg |
| Certifications | CE, UL, CSA, RoHS compliant |
FAQ
FAQ
Q1: What is the main function of the Bently Nevada 136711-01 Temperature Module?
A1: It measures and monitors temperature signals from thermocouples or RTDs in machinery protection systems.
Q2: Which system is this module compatible with?
A2: It is designed for use with the Bently Nevada 3500 Monitoring System.
Q3: What types of temperature sensors can it support?
A3: It supports both thermocouple and RTD (Resistance Temperature Detector) inputs.
Q4: How many input channels does it have?
A4: The module features four independent input channels.
Q5: What is the measurement accuracy?
A5: It provides an accuracy of ±0.1% of full scale.
Q6: How is power supplied to the module?
A6: Power is supplied through the 3500 rack backplane at a nominal 24 VDC.
Q7: What is the typical operating environment?
A7: It operates between 0°C and +65°C with 5–95% non-condensing humidity.
Q8: Does the module provide electrical isolation?
A8: Yes, it provides isolation between channels and between channels and ground.
Tags
Packing & Delivery
We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.
For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.
Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.