Technical Specifications
| Parameter | Specification |
|---|---|
| Model | ABB SYN 5201a-Z,V211 3BHB006714R0211 |
| Type | Synchronization Device |
| Function | Provides synchronization between generator and grid systems |
| Application | Used in power generation and industrial automation systems |
| Supply Voltage | 24 V DC nominal |
| Power Consumption | Approx. 10 W |
| Synchronization Inputs | Generator voltage, grid voltage, and phase reference signals |
| Output Signals | Relay contacts for synchronization command |
| Synchronizing Range | Frequency difference ≤ ±2 Hz; Voltage difference ≤ ±10% |
| Phase Angle Range | 0°–360° |
| Accuracy | ±0.5° phase accuracy |
| Communication Interface | RS-485 / Modbus RTU |
| Isolation Protection | Galvanic isolation between input, output, and communication |
| Indication | LED indicators for synchronization status and fault conditions |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5% – 95% RH, non-condensing |
| Mounting Type | Panel or DIN rail mounting |
| Protection Class | IP20 |
| Compliance | IEC 60255, CE, and UL standards |
| Dimensions | 226 × 171 × 220 mm |
| Weight | 4 kg |
FAQ
FAQ
Q1: What is the main purpose of the ABB SYN 5201a-Z,V211 device?
A1: The SYN 5201a-Z,V211 is designed to synchronize generators or parallel power systems with the electrical grid by matching voltage, frequency, and phase.
Q2: What synchronization parameters does the device monitor?
A2: It monitors voltage, frequency, and phase angle differences between the generator and grid.
Q3: How accurate is the synchronization process?
A3: The device provides synchronization accuracy within ±0.5° of the phase angle.
Q4: Does the SYN 5201a-Z,V211 support communication interfaces?
A4: Yes, it supports RS-485 with Modbus RTU protocol for integration into control systems.
Q5: What kind of outputs does the synchronization device provide?
A5: It provides relay contact outputs to initiate synchronization commands and control breakers.
Q6: Can the SYN 5201a-Z,V211 be used with multiple generator systems?
A6: Yes, it can be configured for use with multi-generator setups in power plant synchronization schemes.
Q7: What type of isolation is provided in the device?
A7: The module provides galvanic isolation between its input, output, and communication circuits to ensure system safety.
Q8: What diagnostic features are included in the SYN 5201a-Z,V211?
A8: The device includes LED indicators and self-diagnostic monitoring for synchronization status and fault conditions.