Technical Specifications
| Item | Specification |
|---|---|
| Model | GE IS210DTURH1A / IS200DTURH1A |
| Product Type | Trip Relay Terminal Board |
| Functional Role | Turbine trip relay signal interface and isolation |
| Output Signal Type | Relay contact output |
| Relay Type | Form C (SPDT) industrial safety relay |
| Number of Relays | 12 trip relays |
| Contact Rating | 5 A @ 250 VAC / 5 A @ 30 VDC (resistive) |
| Coil Voltage | 24 VDC |
| Coil Consumption | 0.9 W per relay |
| Isolation Method | Reinforced isolation between logic and field wiring |
| Isolation Voltage | 2,000 VAC |
| Switching Time | < 10 ms |
| Mechanical Life | 10,000,000 operations |
| Electrical Life | 100,000 operations at rated load |
| Suppression Circuit | Integrated flyback and surge suppression |
| Fail-Safe Design | De-energize-to-trip logic |
| Interface Type | Backplane connector and ribbon cable |
| Mounting Type | Control rack installation |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Operating Humidity | 5–95% RH (non-condensing) |
| PCB Material | FR-4 industrial laminate |
| Coating | Conformal coated for industrial environment |
| Dimensions | 240 × 165 × 32 mm |
| Weight | 0.62 kg |
FAQ
FAQ
Q1: What is the primary function of this terminal board?
A1: It distributes and switches trip commands from the control processor to field-level trip circuits through safety relays.
Q2: What does de-energize-to-trip mean in practice?
A2: Loss of control power or internal failure will cause the relays to release automatically, forcing the turbine into a safe shutdown state.
Q3: Can the trip contacts be wired in series for higher safety integrity?
A3: Yes, contacts can be configured in series or in voting logic at the system level to achieve higher protection reliability.
Q4: Is surge protection built into the relay outputs?
A4: The board includes suppression circuits to reduce voltage spikes caused by inductive loads such as solenoids and contactors.
Q5: How does the control system detect relay health?
A5: Relay states are monitored via feedback channels in the controller, enabling detection of failed or stuck contacts.
Q6: Is the board suitable for safety-critical applications?
A6: It is engineered specifically for turbine protection systems where deterministic response and fail-safe behavior are required.
Q7: Can the relays be driven independently?
A7: Each relay is individually controlled, allowing selective tripping based on logic conditions or protection thresholds.
Q8: Does the board require manual configuration or jumpers?
A8: No local configuration is required; all operational logic is defined in the control system software.