Technical Specifications
| Item | Specification |
|---|---|
| Model | Ovation 5X00701G02 |
| Product Type | Analog Output Module |
| Function | Digital-to-analog signal conversion for control outputs |
| Number of Channels | 8 |
| Output Signal Types | 0–10 V, 1–5 V, 4–20 mA |
| Output Resolution | 16-bit |
| Output Accuracy | ±0.1% full scale |
| Output Load Capacity | Voltage: ≥ 1 kΩ, Current: ≤ 600 Ω |
| Output Update Rate | < 20 ms |
| Isolation Type | Channel-to-system isolation |
| Drift | < 50 ppm/°C |
| Calibration | Software configurable |
| Overrange Protection | Supported |
| Output Stability | Long-term stable reference |
| Electrical Noise Rejection | High common-mode rejection |
| Communication Interface | Ovation system bus |
| Field Wiring Type | Plug-in terminal blocks |
| Mounting Method | Chassis mounted |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5–95% RH |
| Power Requirement | Supplied by system backplane |
| Power Consumption | < 7 W |
| Dimensions (L × W × H) | 280 × 30 × 170 mm |
| Weight | 0.8 kg |
FAQ
FAQ
Q1: What is the primary role of this analog output module?
A1: It converts digital control values into precise analog signals for field instruments and actuators.
Q2: What output types are supported?
A2: The module supports both voltage and current output standards including 0–10 V and 4–20 mA.
Q3: Is channel isolation provided?
A3: Yes, each channel is isolated from the system to reduce noise and ground loop issues.
Q4: How accurate are the output signals?
A4: Outputs are controlled with high-resolution conversion and stable reference circuits for precision control.
Q5: Can output ranges be configured by software?
A5: Yes, all output ranges and scaling parameters are configured in the control system software.
Q6: How does the module handle electrical interference?
A6: It uses noise rejection circuits and stable internal references to maintain output signal integrity.
Q7: What happens if an output is overloaded?
A7: Built-in protection prevents damage and ensures stable recovery once the fault is removed.
Q8: Is calibration required after installation?
A8: Initial calibration parameters are factory set; recalibration is only required during long-term maintenance.