Bently Nevada 200200-05-05 TrendMaster® proTIM‑R
Bently Nevada 200200-05-05 TrendMaster® proTIM‑R
Bently Nevada 200200-05-05 TrendMaster® proTIM‑R
Bently Nevada 200200-05-05 TrendMaster® proTIM‑R
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376

Manufacturer:Bently Nevada

Product Number:200200-05-05

Product Type:TrendMaster® proTIM‑R

Origin:

Dimensions:86.2 mm × 100.9 mm × 52.9 mm

Weight :0.35 kg


FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the purpose of the TrendMaster proTIM‑R module?
A1: It provides two independent measurement channels for vibration and/or temperature monitoring as part of a TrendMaster® Pro condition monitoring system, helping detect machine health issues early.

Q2: What types of sensors can be connected to this module?
A2: Supported sensors include A-V vibration channels, low-frequency A-V, A-V with acceleration enveloping (AE), K-type thermocouples, and Platinum RTDs.

Q3: Can the module measure both vibration and temperature?
A3: Yes, depending on the channel configuration, it can measure vibration (velocity) and temperature via the appropriate sensors.

Q4: How precise are the vibration measurements?
A4: Vibration outputs have a resolution of 0.025 mm/s and an accuracy of ±15 % at 80 Hz for standard A-V channels.

Q5: What environmental conditions can the proTIM‑R operate in?
A5: It is designed for industrial environments with operating temperatures from –40 °C to +70 °C and tolerance for condensing humidity.

Q6: What is the temperature measurement range and accuracy?
A6: Temperature measurement ranges from –18 °C to +204 °C, with a resolution of 0.07 °C. Accuracy is ±8 °C for K-Type thermocouples and ±4.45 °C for RTDs.

Q7: How is the module installed?
A7: The unit is DIN-rail mounted inside control panels or racks for integration with machinery condition monitoring systems.

Q8: Are accessories included with this module?
A8: This product is supplied without accessories; sensor cables and mounting hardware must be purchased separately.