Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | SE4001S2T1B2 |
| Manufacturer | Emerson |
| Product Series | DeltaV™ S-Series Traditional I/O |
| Product Type | Discrete Input Module with Fused 8-Channel Terminal Block |
| Application | Digital Signal Monitoring and Acquisition |
| Input Channels | 8 Channels |
| Input Voltage | 24 VDC Nominal |
| Input Current | Up to 10 mA per Channel |
| Isolation Voltage | 500 VDC Between Channels and Ground |
| Response Time | < 5 ms |
| Wiring Size | 16 AWG to 20 AWG |
| Power Consumption | < 1.5 W |
| MTBF | > 100,000 hours |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Terminal Block Type | Fused 8-channel terminal block |
| Mounting Type | DeltaV S-Series Carrier |
| Dimensions (L × W × H) | ~100 mm × 120 mm × 30 mm |
| Weight | ~0.25 kg |
| Country of Origin | United States |
FAQ
FAQ
Q1: What is the Emerson SE4001S2T1B2 used for?
It is used to read digital (ON/OFF) signals from field devices such as switches, pushbuttons, and relay contacts in a DeltaV control system.
Q2: How is SE4001S2T1B2 different from SE4001S2T1B1?
The B2 version includes a fused terminal block, which provides additional protection for each channel’s field wiring, while B1 uses a standard terminal block.
Q3: How many input channels does it have?
It provides 8 discrete input channels.
Q4: What is the operating voltage?
It operates at 24 VDC nominal input for industrial digital signals.
Q5: What is the purpose of the fuse in this module?
The fuse protects field wiring and connected devices from overcurrent conditions and helps isolate faults quickly without affecting the entire module.
Q6: What is the response time?
The module responds in less than 5 milliseconds, suitable for fast digital signal processing.
Q7: What are its environmental limits?
It operates between -20°C and +70°C, and up to 95% non-condensing humidity.
Q8: Does it require calibration or maintenance?
No calibration is required. Only periodic inspection of wiring, terminals, and fuses is recommended.