Welcome to NewPLC!

GE IC693MDL930H Isolated Relay Output Module

GE IC693MDL930H Isolated Relay Output Module

Release time:2026-07-28

Views:149

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
GE IC693MDL930H Isolated Relay Output Module
GE IC693MDL930H Isolated Relay Output Module
GE IC693MDL930H Isolated Relay Output Module
GE IC693MDL930H Isolated Relay Output Module
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Manufacturer GE Fanuc (now Emerson Automation)
Product Model IC693MDL930H
Product Type Isolated Relay Output Module
Series Series 90-30 PLC
Function Provides relay outputs for controlling AC and DC field devices
Output Type Normally Open (N.O.) Relay Outputs
Number of Output Points 8 isolated outputs
Output Isolation Each output individually isolated
Rated Output Voltage 24 VDC, 120/240 VAC (Nominal)
Operating Voltage Range 5–30 VDC; 5–250 VAC, 50/60 Hz
Maximum Output Current 4 A per output (resistive)
Pilot Duty Rating 2 A per output
Maximum Module Load 20 A (UL installations)
Minimum Load Current 10 mA
Maximum Inrush Current 5 A
ON Response Time 15 ms maximum
OFF Response Time 15 ms maximum
Backplane Power Consumption 6 mA @ 5 VDC bus; 70 mA @ 24 V relay bus (all outputs ON)
Isolation Voltage 1500 VAC for 1 minute; 250 VAC continuous
Status Indicators One LED per output point
Terminal Block 20-screw removable terminal block
Mounting Any I/O slot in a Series 90-30 baseplate
Compatible PLC GE Fanuc Series 90-30 PLC
Operating Temperature 0°C to +60°C (32°F to +140°F)
Storage Temperature -40°C to +85°C (-40°F to +185°F)
Relative Humidity 5%–95% RH (Non-condensing)
Dimensions (H × W × D) Approx. 131 × 41 × 140 mm (5.16 × 1.61 × 5.51 in)
Weight Approx. 0.45 kg (0.99 lb)
Typical Applications Contactors, Solenoid Valves, Motor Starters, Alarm Devices, Indicator Lamps
Hardware Revision H
Warranty 12 Months

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What is the IC693MDL930H used for?
The IC693MDL930H is an 8-point isolated relay output module for the GE Fanuc Series 90-30 PLC. It controls external AC or DC devices such as motor starters, relays, solenoid valves, indicator lamps, and alarms through independent relay contacts.

Q2: How many outputs does the IC693MDL930H provide?
The module provides eight normally open relay outputs, with each output electrically isolated from the others. This design allows different voltages or circuits to be switched independently.

Q3: What voltage and current ratings are supported?
The IC693MDL930H supports 5–30 VDC and 5–250 VAC (50/60 Hz) operating voltages. Each relay output can switch up to 4 A resistive load, making it suitable for a wide range of industrial control applications.

Q4: Can the module switch both AC and DC loads?
Yes. The relay outputs are designed to switch both AC and DC loads, giving users greater flexibility when controlling different types of industrial equipment.

Q5: What types of devices are commonly connected to the IC693MDL930H?
Typical field devices include contactors, motor starters, solenoid valves, pilot lights, alarms, industrial relays, and other electrically operated equipment requiring relay control.

Q6: How are output statuses indicated?
The module includes individual LED indicators for each output channel, allowing maintenance personnel to quickly identify the operating status of every relay point.

Q7: What does the “H” revision indicate?
The “H” suffix identifies a specific hardware revision of the IC693MDL930 module. It remains fully compatible with Series 90-30 PLC systems while incorporating manufacturing and lifecycle updates introduced during production.

Q8: What should be checked before replacing the IC693MDL930H?
Before replacement, verify the PLC baseplate compatibility, output load voltage, current requirements, terminal wiring, relay contact ratings, and field power supply. Confirming these items helps ensure reliable operation and protects both the module and connected equipment.


Tags

Packing & Delivery

We will use wear-resistant cartons to seal the boxes, and take photos for your confirmation before sealing. We will pack the boxes only after confirmation.

For express delivery, we will use DHL, UPS, TNT, FedEx and EMS.

Please rest assured that we have a deep cooperation with express delivery companies and can ensure that your goods are delivered to you in good condition.


Leave Your Message


Leave a message