Welcome to NewPLC!

Epro PR6423/011-000 8mm Eddy Current Sensor

Epro PR6423/011-000 8mm Eddy Current Sensor

Release time:2025-06-12

Views:305

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24

Send Inquiry
Description
FAQ
Products Description
Epro PR6423/011-000 8mm Eddy Current Sensor
Epro PR6423/011-000 8mm Eddy Current Sensor
Epro PR6423/011-000 8mm Eddy Current Sensor
Epro PR6423/011-000 8mm Eddy Current Sensor
Company Information
E-mail [email protected]
Mobile +8613950166376
Whatsapp +8613950166376
WeChat 13950166376
Click to rate this post!
[Total: 0 Average: 0]

Technical Specifications

Parameter Specification
Linear Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils)
Incremental Scale Factor (ISF) 8 V/mm (203.2 mV/mil) ±5% (0 to +45°C)
Deviation from Best Fit Line (DSL) ±0.025 mm (±1 mil) (0 to +45°C)
Minimum Shaft Diameter 25 mm (0.98 in)
Target Material 42CrMo4 (AISI/SAE 4140), others on request
Protection Class IP66 (IEC 60529)
Operating Temperature (Sensor + Cable) -35°C to +180°C (-31°F to 356°F)
Operating Temperature (Cable & Connector) -35°C to +150°C (-31°F to 302°F)
Sensor Tip Material PEEK (Polyether Ether Ketone)
Case Material Stainless Steel
Cable Material PTFE (Polytetrafluoroethylene)
Connector Material Nickel-plated Brass
Weight (Sensor + 1m Cable) Approx. 100 g (0.1 kg)
Sensor Head Diameter 8 mm

FAQ
Click to rate this post!
[Total: 0 Average: 0]

Frequently Asked Questions (FAQ)

Q1: What is the measurement range of the PR6423/011-000 sensor?
A1: The linear measurement range is 2 mm (80 mils).

Q2: What is the initial gap required for optimal performance?
A2: The initial air gap is 0.5 mm (20 mils).

Q3: What is the minimum shaft diameter this sensor can detect?
A3: The minimum measurable shaft diameter is 25 mm (0.98 in).

Q4: What materials is the sensor made from?
A4: The sensor tip is PEEK, the case is stainless steel, the cable is PTFE, and the connector is nickel-plated brass.

Q5: What are the operating temperature limits of the sensor?
A5: The sensor can operate between -35°C and +180°C.

Q6: Does the sensor have hazardous area certifications?
A6: Yes, it is compliant with ATEX, IEC-Ex, and CSA standards for intrinsic safety and non-sparking applications.

Q7: What is the deviation from linearity (DSL) of this sensor?
A7: It is ±0.025 mm (±1 mil) over the temperature range of 0 to +45°C.

Q8: What is the weight and size of the sensor head?
A8: The sensor head is 8 mm in diameter and weighs approximately 0.1 kg including 1m cable.