Technical Specifications

Parameter Specification
Model Number IC660BBA101
Input Type RTD (Platinum, Nickel, Copper)
Channels 6 channels (in 3 isolated groups of 2 circuits each)
Isolation (Group to Group) 300 V
Isolation (Block to Block) 1500 V
Input Resolution 0.1°C
Accuracy at 25°C ±0.5°C typical (Platinum/Nickel), ±5°C typical (Copper)
Linearization Types DIN 43760 Platinum/Nickel, Copper, Linear
Resistance Range 0–5000 Ohms
Update Frequency Every 400 ms, 800 ms, or 1600 ms
Input Filter Time Configurable: 400, 800, or 1600 ms
Diagnostic Functions Input short, internal fault, wiring error, open wire, over/under range, high/low alarms
Power Supply 115 VAC / 125 VDC
Power Supply Voltage 93–132 VAC @ 47–63 Hz, or 105–145 VDC
Power Consumption 7 W max
LEDs Unit OK, I/O Enabled
Size (H x W x D) 224.4 × 88.9 × 100 mm
Weight 1.8 kg
Compatibility IC66*HHM501D handheld monitor (v3.5+), IC697/IC600/IC550 PLCs

FAQ
Click to rate this post!
[Total: 0 Average: 0]

FAQ

Q1: What types of RTDs are supported by the IC660BBA101?
A1: It supports platinum, nickel, and copper RTDs with automatic linearization based on the selected type.

Q2: Does the module offer group-to-group isolation?
A2: Yes, it offers 300V isolation between each of the three input groups.

Q3: What is the input accuracy?
A3: At 25°C, platinum/nickel RTDs have ±0.5°C typical accuracy; copper RTDs have ±5°C typical accuracy.

Q4: How often are inputs updated?
A4: Input update rates can be configured to 400 ms, 800 ms, or 1600 ms.

Q5: Does it support self-diagnostics?
A5: Yes, it provides input short, open wire, wiring error, internal fault, over/under range, and high/low alarm diagnostics.

Q6: What are the power requirements?
A6: It requires either 115 VAC or 125 VDC and consumes up to 7 W.

Q7: What are its dimensions and weight?
A7: The dimensions are 224.4 × 88.9 × 100 mm, and it weighs 1.8 kg.

Q8: Is recalibration required after installation?
A8: No, the module is factory-calibrated and does not require recalibration.