Technical Specifications
| Parameter | Description |
|---|---|
| Model Number | 330101-13-37-10-02-05 |
| System Type | 3300 XL 8 mm Proximity Probe |
| Linear Range | 2 mm (80 mils), approx. –1 to –17 Vdc |
| Recommended Gap Voltage | -9 Vdc (approx. 1.27 mm or 50 mils) |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) ±5% (5m/1m) ±6.5% (9m) |
| Deviation from Best Fit Line | ≤ ±0.025 mm (±1 mil) for 1/5m, ≤ ±0.038 mm (±1.5 mils) for 9m |
| Frequency Response | 0 to 10 kHz, +0, -3 dB |
| Probe Tip Material | PPS (Polyphenylene sulfide) |
| Probe Case Material | AISI 303 or 304 stainless steel |
| Probe Cable | 75 Ω triaxial, FEP insulated (standard); PFA for extended temperature |
| Minimum Target Size | 15.2 mm (0.6 in) diameter (flat target) |
| Minimum Shaft Diameter | 50.8 mm (2 in), recommended ≥ 76.2 mm (3 in) |
| Probe Operating Temperature | -52°C to +177°C (standard), up to +218°C for ETR tip |
| Extension Cable Temp. Range | -52°C to +177°C (standard), up to +260°C for ETR cable |
| Proximitor Sensor Temp. Range | Operating: -52°C to +100°C; Storage: -52°C to +105°C |
| Relative Humidity Resistance | <3% change in ASF @ 93% humidity (IEC 68 2 3) for 56 days |
| Pressure Seal | Viton® O-ring, not pressure tested |
| Probe Cable Pull Strength | 330 N (75 lbf) |
| Total Length | 1.0 meter |
| Total Weight | 0.323 kg |
FAQ
FAQ
Q1: What is the recommended gap setting for the 330101-13-37-10-02-05 probe?
A1: The recommended gap is approximately 1.27 mm (50 mils), corresponding to a -9 Vdc output.
Q2: Is this probe suitable for high-temperature environments?
A2: Yes, the ETR version supports probe temperatures up to +218°C and cable temperatures up to +260°C.
Q3: What is the configured length of this probe model?
A3: This model is configured to a total length of 1.0 meter and does not require an extension cable.
Q4: Is the probe sensitive to power supply fluctuations?
A4: No, it is designed with supply sensitivity less than 2 mV per volt of input variation.
Q5: Does this system require matched calibration of components?
A5: No, the 3300 XL system supports complete interchangeability without matching or bench calibration.
Q6: What is the maximum pull strength the probe can withstand?
A6: The probe can withstand up to 330 N (75 lbf) between the probe body and cable.
Q7: Is the probe affected by 60 Hz magnetic field interference?
A7: It has excellent immunity; the maximum effect is around 0.0348 mil pp/Gauss depending on gap.
Q8: Does temperature variation impact measurement accuracy?
A8: Yes, but within -35°C to +120°C, the ISF remains within ±10% and DSL within ±0.076 mm (±3 mils).